Paper
30 July 2002 Alignment procedure and divergence behavior in capillary optics: first results with x-ray tubes and synchrotron radiation
Giorgio Cappuccio, Sultan B. Dabagov
Author Affiliations +
Proceedings Volume 4765, International Conference on X-ray and Neutron Capillary Optics; (2002) https://doi.org/10.1117/12.489761
Event: International Conference on X-ray and Neutron Capillary Optics, 2001, Zvenigorod, Russian Federation
Abstract
Due to the low value of the critical angle, the main problem is using a polycapillary lens is to position it correctly with respect to the x-ray source. We have developed a recursive procedure for fast and precise alignment by means of a four-circle diffractometer and a Cu x-ray tube. After the alignment we observed the focusing effect on a fluorescent target and measured an increase of about 30 in the local density of the x-ray beam. During the experiments a sharp decrease in the beam divergence behind the capillary structures was also detected. This unexplained fact, already mentioned in the past by several reserachers, was explained for the first time by our group in the framework of the wave scattering theory. The same alignment procedure was successfully repeated using synchrotron radiation at the Elettra storgae ring at Trieste. The focal spot position was evaluated by a set of photo images. In the same experiment we also tested and evaluated the operating characteristics of a straight polycapillary lens.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Giorgio Cappuccio and Sultan B. Dabagov "Alignment procedure and divergence behavior in capillary optics: first results with x-ray tubes and synchrotron radiation", Proc. SPIE 4765, International Conference on X-ray and Neutron Capillary Optics, (30 July 2002); https://doi.org/10.1117/12.489761
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Capillaries

Synchrotron radiation

X-rays

Alignment procedures

X-ray diffraction

X-ray optics

Electromagnetic scattering theory

RELATED CONTENT

Capillary optics: experimental study by the S-60
Proceedings of SPIE (July 30 2002)
Divergence of x-ray beams transmitted by capillary structures
Proceedings of SPIE (November 28 2000)
Diffraction of x rays in capillary waveguides
Proceedings of SPIE (September 29 1999)
X-ray radiation filtration by means of Kumakhov lenses
Proceedings of SPIE (July 30 2002)

Back to Top