Paper
30 September 2004 Cooling of ground-based telescope instrumentation: the LINC-NIRVANA cryostat
Author Affiliations +
Abstract
The MPIA in Heidelberg has built many instruments for IR observation over the years. While the previous instruments were moderate in size and could easily be enclosed in a liquid nitrogen dewar, future instruments will require different cooling concepts. The use of Gifford McMahon coolers was chosen for some instruments, but has the disadvantage of low frequency vibrations. The recently-developed pulse tube coolers have lower vibrations but other disadvantages. For the LINC-NIRVANA cryostat, we plan to build a cooling system with a constant flow of Helium through a heat exchanger inside the cryostat. This cooling concept could also be expanded to future instrumentation for the next generation of telescopes.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Werner Laun, Harald Baumeister, and Peter Bizenberger "Cooling of ground-based telescope instrumentation: the LINC-NIRVANA cryostat", Proc. SPIE 5492, Ground-based Instrumentation for Astronomy, (30 September 2004); https://doi.org/10.1117/12.551497
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Helium

Nitrogen

Liquids

Telescopes

Cryogenics

Temperature metrology

Cooling systems

RELATED CONTENT

SIRTF telescope test facility
Proceedings of SPIE (September 29 1995)
IRAS Telescope Cryotest Chamber
Proceedings of SPIE (February 01 1985)
First concept for the E-ELT cryogenic infrastructure
Proceedings of SPIE (July 22 2010)