Paper
29 September 2004 Low-noise charge injection in the CCD22
Author Affiliations +
Abstract
The inclusion of a charge injection structure on a charge coupled device (CCD) allows for the mitigation of charge transfer loss which can be caused by radiation induced charge trapping defects. Any traps present in the pixels of the CCD are filled by the injected charge as it is swept through the device and consequently, the charge transfer efficiency is improved in subsequently acquired images. To date, a number of different types of CCD have been manufactured featuring a variety of charge injection techniques. The e2v Technologies CCD22, used in the EPIC MOS focal plane instruments of XMM-Newton, is one such device and is the subject of this paper. A detailed understanding of charge injection operation and the use of charge injection to mitigate charge transfer losses resulting from radiation damage to CCDs will benefit a number of space projects planned for the future, including the ESA GAIA and X-ray Evolving Universe Spectrometry (XEUS) missions. The charge injection structure and mode of operation of the CCD22 are presented, followed by a detailed analysis of the uniformity and repeatability of the charge injection amplitude across the columns of the device. The effects of proton irradiation on the charge injection characteristics are also presented, in particular the effect of radiation induced bright pixels on the injected charge level.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David R. Smith, Andrew D. Holland, Ian B. Hutchinson, Antony F. Abbey, Peter J. Pool, David Burt, and David Morris "Low-noise charge injection in the CCD22", Proc. SPIE 5501, High-Energy Detectors in Astronomy, (29 September 2004); https://doi.org/10.1117/12.551393
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Electrons

Radiation effects

Molybdenum

Space operations

X-rays

Calibration

RELATED CONTENT

Swift X-Ray Telescope
Proceedings of SPIE (December 13 2000)
EMCCDs for space applications
Proceedings of SPIE (June 15 2006)
JET-X attitude monitor for the Spectrum-RG mission
Proceedings of SPIE (October 01 1993)
X-ray imaging spectrometer (XIS) on board Astro-E2
Proceedings of SPIE (March 11 2003)

Back to Top