Paper
25 April 2005 Time-intensity based optoacoustic flow measurements with gold nanoparticles
Pai-Chi Li, Chen-Wei Wei, Chao-Kang Liao, Hsiao-Chien Tseng, Yen-Ping Lin, Chia-Chun Chen
Author Affiliations +
Abstract
The indicator-dilution theory has been used for flow rate measurements in various imaging modalities, including magnetic resonance imaging, computed tomography and ultrasound. The experimental procedure generally involves the injection of a dose of indicator (i.e., the contrast agent), after which the concentration of the agent is monitored as a function of time; it is therefore also known as the time-intensity method. Although the time-intensity method has been widely applied to other imaging modalities, it has not been demonstrated with optoacoustic imaging. In this study, we experimentally test the hypothesis that quantitative blood flow measurements are feasible with the time-intensity based method in optoacoustic imaging. Gold nanospheres (broad band absorption spectrum peaks at 520 nm) were used as the optoacoustic contrast agent. The imaging system consisted of a frequency-doubled Nd:YAG laser operating at 532 nm for optical illumination, and an ultrasonic single crystal transducer with a center frequency of 3.5 MHz and a focal depth of 7 cm for detection. The volumetric flow rate ranged from 0.23 to 4.29 ml/sec, and the volume of the mixing chamber was from 30 to 80 ml. Results show good agreement between the measured mean transit times and the predicted time constants (correlation coefficient higher than 0.88), thus demonstrating the feasibility of the time-intensity based flow measurement technique. In addition to describing the method and experimental results, issues regarding the system sensitivity and estimation of the dilution transfer function are also discussed.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pai-Chi Li, Chen-Wei Wei, Chao-Kang Liao, Hsiao-Chien Tseng, Yen-Ping Lin, and Chia-Chun Chen "Time-intensity based optoacoustic flow measurements with gold nanoparticles", Proc. SPIE 5697, Photons Plus Ultrasound: Imaging and Sensing 2005: The Sixth Conference on Biomedical Thermoacoustics, Optoacoustics, and Acousto-optics, (25 April 2005); https://doi.org/10.1117/12.591106
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Nanoparticles

Gold

Toxic industrial chemicals

Imaging systems

Blood circulation

Absorption

Nd:YAG lasers

Back to Top