7 September 2006 Specific resistivity of glassy-carbon and its temperature dependence
Author Affiliations +
Abstract
Specific resistivity of glassy carbon material is reported as a function of temperature in interval [0 - 800 C]. Concurrent determination of voltage, current, and temperature is described. Temperature is assessed radiometrically. At room temperature, specific resistivity of glassy carbon has been measured to be equal to 3.02 x10-5 Ωm. At higher temperatures, specific resisitvity of glassy carbon decreases linearly with temperature, with negative thermal coefficient of -1.25 x 10-8 Ωm/C.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marija Strojnik "Specific resistivity of glassy-carbon and its temperature dependence", Proc. SPIE 6307, Unconventional Imaging II, 63070S (7 September 2006); https://doi.org/10.1117/12.683358