Paper
2 September 2008 IR spectrometer using 90-degree off-axis parabolic mirrors
Author Affiliations +
Abstract
A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light Source at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output IR recording camera. With an initial wavelength range of 1500-4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the second parabolic mirror, any spectral region of interest within the InSb camera array's sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement singlepoint pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert M. Malone, Daniel H. Dolan, Richard G. Hacking, and Ian J. McKenna "IR spectrometer using 90-degree off-axis parabolic mirrors", Proc. SPIE 7068, Optical System Alignment and Tolerancing II, 706808 (2 September 2008); https://doi.org/10.1117/12.793790
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Infrared cameras

Mirrors

Prisms

Spectroscopy

Infrared spectroscopy

Infrared imaging

RELATED CONTENT

Image stabilization for Airborne Infrared Spectrometer
Proceedings of SPIE (October 10 2018)
Analysis of working range in IR camera measurement
Proceedings of SPIE (May 20 2009)
Infrared spectrometer/imager for the ESO VLT
Proceedings of SPIE (July 01 1990)
SIRTF instrument concepts
Proceedings of SPIE (October 01 1993)

Back to Top