9 April 2009 SAR measurement in MRI: an improved method
Rocco Romano, Fausto Acernese, Pietro Luigi Indovina, Fabrizio Barone
Author Affiliations +
Abstract
During an MR procedure, the patient absorbs a portion of the transmitted RF energy, which may result in tissue heating and other adverse effects, such as alterations in visual, auditory and neural functions. The Specific Absorption Rate (SAR), in W/kg, is the RF power absorbed per unit mass of tissue and is one of the most important parameters related with thermal effects and acts as a guideline for MRI safety. Strict limits to the SAR levels are imposed by patient safety international regulations (CEI - EN 60601 - 2 - 33) and SAR measurements are required in order to verify its respect. The recommended methods for mean SAR measurement are quite problematic and often require a maintenance man intervention and long stop machine. For example, in the CEI recommended pulse energy method, the presence of a maintenance man is required in order to correctly connect the required instrumentation; furthermore, the procedure is complex and requires remarkable processing and calculus. Simpler are the calorimetric methods, also if in this case long acquisition times are required in order to have significant temperature variations and accurate heat capacity knowledge (CEI - EN 60601 - 2- 33). The phase transition method is a new method to measure SAR in MRI which has the advantages to be very simple and to overcome all the typical calorimetric method problems. It does not require in gantry temperature measurements, any specific heat or heat capacity knowledge, but only mass and time measurement. Furthermore, in this method, it is possible to show that all deposited SAR power can be considered acquired and measured.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Rocco Romano, Fausto Acernese, Pietro Luigi Indovina, and Fabrizio Barone "SAR measurement in MRI: an improved method", Proc. SPIE 7295, Health Monitoring of Structural and Biological Systems 2009, 72952P (9 April 2009); https://doi.org/10.1117/12.814127
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Synthetic aperture radar

Tissues

Scanners

Magnetic resonance imaging

Temperature metrology

Time metrology

Cesium

RELATED CONTENT

The phase transition method for SAR measurement in MRI
Proceedings of SPIE (March 09 2014)
A new method for SAR measurement in MRI
Proceedings of SPIE (April 10 2008)
The phase transition method for SAR measurement in MRI
Proceedings of SPIE (April 09 2010)
A no-calorimetric method for measuring SAR in MRI
Proceedings of SPIE (April 18 2011)
RF hyperthermia using conductive nanoparticles
Proceedings of SPIE (March 02 2010)

Back to Top