Paper
15 April 2011 Linear damage location using fiber optic acoustic emission sensors for structure health monitoring
Tao Fu, Zhichun Zhang, Zaiwen Lin, Zhenhua Yao, Jinsong Leng
Author Affiliations +
Abstract
We have previously reported a novel Fiber Optic Acoustic Emission Sensor (FOAES), which was specially processed based on fused-tapered optical fiber coupler. The FOAES was packed with silica capillary tube so that it could be embedded in damage monitoring of composite materials. But the linear damage location of acoustic emission using double sensors had not been tried. In this paper, linear damage location experiments with double sensors were tested on aluminium plate and composite plate. The test results showed that linear damage position was identified within ±6.25 mm on aluminium plate and ±4.84 mm on composite plate.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tao Fu, Zhichun Zhang, Zaiwen Lin, Zhenhua Yao, and Jinsong Leng "Linear damage location using fiber optic acoustic emission sensors for structure health monitoring", Proc. SPIE 7982, Smart Sensor Phenomena, Technology, Networks, and Systems 2011, 79820X (15 April 2011); https://doi.org/10.1117/12.880192
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Acoustics

Composites

Fiber optics sensors

Acoustic emission

Wave propagation

Aluminum

Back to Top