Paper
18 August 2011 Study on transient noise of CCD camera induced by γ-ray
Bao-jun Duan, Dong-wei Hei, Gu-zhou Song, Ji-ming Ma, Zhan-hong Zhang, Chang-cai Han, Yan Song, Ming Zhou, Lan Lei
Author Affiliations +
Abstract
In this paper, based on the mechanism of CCD camera, an event-based simulation method of γ-ray-induced transient noise was developed, which applying MCNP5 Code based on Monte Carlo methods. On the mono-energy γ-ray sources, the transient noises of two different CCD cameras have been measured at different doses (from 0.001mR to 1mR) and different incidence angles. The 60Co and 137Cs were used as the mono-energy γ-ray sources, and the Compton Scattering technique were adopted to get lower energy γ-ray sources. In order to get the pure transient noise induced by γ-ray, a method was advanced for extracting the transient noise from the image mixed the background noise. And the transient noise was characterized, including the number of noise clusters, the noise intensity spectrum and the size spectrum of noise clusters. The variation characteristics of noise have been draw from the simulation and experiment, which induced by γ-rays of different dose, or different energy or different incidence angle.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bao-jun Duan, Dong-wei Hei, Gu-zhou Song, Ji-ming Ma, Zhan-hong Zhang, Chang-cai Han, Yan Song, Ming Zhou, and Lan Lei "Study on transient noise of CCD camera induced by γ-ray", Proc. SPIE 8194, International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Imaging Detectors and Applications, 81943D (18 August 2011); https://doi.org/10.1117/12.901769
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
CCD cameras

Charge-coupled devices

Cameras

Monte Carlo methods

CCD image sensors

Electrons

Imaging systems

RELATED CONTENT


Back to Top