6 March 2013 Motion correction of rodent thoracic PET image using radioactive bead and MRI image
Jung Woo Yu, Sang-Keun Woo, Yong Jin Lee, In Ok Ko, Ran Ji Yoo, Joo Hyun Kang, Byung Il Kim, Yong Hyun Chung, Sang Moo Lim, Kyeong Min Kim
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 866847 (2013) https://doi.org/10.1117/12.2007124
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
PET image of tumor located in thoracic region was affected by various organ motions such as respiration and heartbeat. Thoracic motion is difficult to estimate and correct accurately using external measurement or anatomical image solely. The aim of this study was to compare the accuracy of motion correction using PET fiducial mark and 3D MRI image. The radioactive bead for PET fiducial mark was realized from molecular sieve contained 0.37 MBq F-18 and placed in thoracic region. PET study was performed using a small animal PET scanner after IV injection of FDG. MRI study was performed using 3-T clinical MRI system with 3D T1-VIBE (TR/TE=5.67/1.42 ms) sequence. Motion corrected PET image was created by mutual information registration with B-Spline interpolation to the mean image after first realignment. FWHM of lung and liver region in static PET image was 4.77±0.87 and 4.81±0.45, respectively. Measured FWHM of lung region in motion corrected PET image using PET fiducial mark and 3D VIBE MRI was measured 4.22±0.09 and 4.59±0.06, respectively. In case of liver region, FWHM was measured 4.47±0.16 and 4.65±0.25 respectively. The improvement of resolution was observed by proper correction method. In this study PET correction was implemented by motion information extracted from various images. These results suggest motion correction would be possible without external device or fiducial mark using MRI motion data. Motion correction using MRI should be considered acquisition method and organ region in accordance with motion characteristics.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jung Woo Yu, Sang-Keun Woo, Yong Jin Lee, In Ok Ko, Ran Ji Yoo, Joo Hyun Kang, Byung Il Kim, Yong Hyun Chung, Sang Moo Lim, and Kyeong Min Kim "Motion correction of rodent thoracic PET image using radioactive bead and MRI image", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 866847 (6 March 2013); https://doi.org/10.1117/12.2007124
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Positron emission tomography

Magnetic resonance imaging

Motion estimation

Liver

Lung

3D magnetic resonance imaging

Data corrections

Back to Top