Paper
11 September 2013 MTF measurement of IRFPA based on double-knife edge scanning method
Cheng-ping Ying, Bin Wu, Heng-fei Wang, Xue-shun Shi, Hong-yuan Liu
Author Affiliations +
Proceedings Volume 8907, International Symposium on Photoelectronic Detection and Imaging 2013: Infrared Imaging and Applications; 890746 (2013) https://doi.org/10.1117/12.2034552
Event: ISPDI 2013 - Fifth International Symposium on Photoelectronic Detection and Imaging, 2013, Beijing, China
Abstract
Modulation transfer function (MTF) is one of the most important parameters of infrared focal plane array (IRFPA). A double-knife edge scanning method is proposed for MTF measurement of IRFPA. In this method, a double-knife edge was used as a target, and the IRFPA under test was positioned in the focal plane of the imaging optical system by a 3-axis translation stage. With an IRFPA data acquisition system, the image of the double-knife edge was restored. By scanning in the direction orthogonal to the double-knife edge image, edge spread function (ESF) curve of each pixel swept across the knife-edge image was obtained. MTF could be calculated from the subsequent fitting, differential and Fourier transformation procedures. With double-knife edge scanning, two ESF curves of double-knife edge were obtained simultaneously, and symmetry of the two ESF curves could be used to evaluate the verticality between photosensitive surface of IRFPA and optical axis of the double-knife edge imaging system. In addition, this method can be used to judge the existing of interference from outside such as vibration, stray light and electrical noise. A measurement facility for IRFPA’s MTF based on double-knife edge scanning method was also established in this study. The facility is composed of double-knife edge imaging optical system, 3-axis translation stage and data acquisition system, et al. As the kernel of the facility, the double-knife edge imaging optical system mainly comprises two symmetrical parabolic mirrors coating with reflective material, and the magnification of the optical system is 1 with an operation wavelength range of (1∼14) μm.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Cheng-ping Ying, Bin Wu, Heng-fei Wang, Xue-shun Shi, and Hong-yuan Liu "MTF measurement of IRFPA based on double-knife edge scanning method", Proc. SPIE 8907, International Symposium on Photoelectronic Detection and Imaging 2013: Infrared Imaging and Applications, 890746 (11 September 2013); https://doi.org/10.1117/12.2034552
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Imaging systems

Optical imaging

Data acquisition

Infrared imaging

Reflectors

Infrared radiation

RELATED CONTENT

Optical design of portable nonmydriatic fundus camera
Proceedings of SPIE (March 08 2017)
Design of target simulator with off-axis RC
Proceedings of SPIE (January 10 2018)
Method of estimating the transfer function of an optical system
Proceedings of SPIE (September 25 2001)
Ultraviolet through infrared imager performance testing
Proceedings of SPIE (September 23 2009)
High-Speed Production Lens Testing
Proceedings of SPIE (October 29 1981)

Back to Top