Paper
10 August 2015 Thermal infrared radiometer calibration and experimental measurements
Author Affiliations +
Proceedings Volume 9620, 2015 International Conference on Optical Instruments and Technology: Optical Sensors and Applications; 96200V (2015) https://doi.org/10.1117/12.2192935
Event: International Conference on Optical Instruments and Technology 2015, 2015, Beijing, China
Abstract
Thermal infrared radiometers play a vital role in obtaining information in field measurements and also in verifying information from remote sensing satellite sensor data. However, the calibration precision of the thermal infrared radiometers directly affects the accuracy of the remote sensing data analysis and application. It is therefore necessary to ensure that the calibration of thermal infrared radiometers is of sufficient and reliable precision. In this paper, the theory of a six-band thermal infrared radiometer (CE 312-2 ASTER) calibration method was introduced, with the calibration being conducted by using a blackbody source in the laboratory. The sources of error during the calibration procedure were analyzed, and the results of the calibration were provided. Then, laboratory experiments using the radiometer were described. The measurements of the surface temperature of a water sample that was contained in a thermostatic water bath, performed by using the radiometer, were compared to the water sample’s temperature controlled by another device. These experiments were used to evaluate the calibration precision of the CE 312-2 ASTER radiometer, by means of assessing the measurement accuracy of the experiments. The results demonstrated that the calibration coefficients of the CE 312-2 ASTER thermal infrared radiometer displayed a very good performance, with highly accurate measurements, and could be used to detect phenomena related to a thermal infrared target.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
JiAn Wei, Difeng Wang, Fang Gong, Bai Yan, and Xianqiang He "Thermal infrared radiometer calibration and experimental measurements", Proc. SPIE 9620, 2015 International Conference on Optical Instruments and Technology: Optical Sensors and Applications, 96200V (10 August 2015); https://doi.org/10.1117/12.2192935
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Radiometry

Temperature metrology

Black bodies

Infrared radiation

Thermography

Precision calibration