Paper
8 March 2017 Distance measurement for rotation center to measurement table using triangulation method
Xicheng Wang, Muzheng Xiao, Chao Wang, Xin Jin, Zhijing Zhang, Kiyoshi Takamasu
Author Affiliations +
Proceedings Volume 10255, Selected Papers of the Chinese Society for Optical Engineering Conferences held October and November 2016; 102553W (2017) https://doi.org/10.1117/12.2268053
Event: Selected Papers of the Chinese Society for Optical Engineering Conferences held October and November 2016, 2016, Jinhua, Suzhou, Chengdu, Xi'an, Wuxi, China
Abstract
Large aspheric mirrors with diameter over 200 mm are widely used in space communication system, large-scale astronomical telescope and X-ray facilities. However the measurement of these mirrors with large slope is a long-term problem. Scanning deflectometry method using autocollimator with rotary stage was proposed for measuring mirrors with large slope. The repeatability of the method has been confirmed as tens of nanometers. However, the absolute accuracy of the method is not confirmed since the distance between the rotation center of the rotary stage and the mirror under measurement is difficult to measure, which strongly affects the measurement accuracy of scanning deflectometry method. In this paper, we have proposed a triangulation method with CMOS sensor for measuring the distance from the rotation center to the measurement table (marble surface). The error analysis shows that the measurement uncertainty of this measurement method is about 40 microns. The repeated experiments show that the measurement accuracy of the proposed method is 49.7 microns, which meets the requirements of large mirror measurement with tens of nanometers’ uncertainty. This method also provides a new solution for the position measurement of the rotation center of the large scale rotary device.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xicheng Wang, Muzheng Xiao, Chao Wang, Xin Jin, Zhijing Zhang, and Kiyoshi Takamasu "Distance measurement for rotation center to measurement table using triangulation method", Proc. SPIE 10255, Selected Papers of the Chinese Society for Optical Engineering Conferences held October and November 2016, 102553W (8 March 2017); https://doi.org/10.1117/12.2268053
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Autocollimators

Distance measurement

Mirrors

Cameras

Deflectometry

Error analysis

CMOS sensors

Back to Top