1.INTRODUCTIONCMOS sensors invade ground applications : mobile phones, digital still camera and so on. Constant integration and miniaturization thanks to the market oblige fabricants to be more and more imaginative and to push the limits of technologies: the use of color filters and micro-lenses is now generalized. However the use of such sensors is quite limited for space applications. For non radiometric applications CMOS COTS imagers could be interesting. The price and the technology improvement are of courses advantages. But radiation behavior of such devices could be a serious drawback. This paper will show some results obtained on such sensors, even if they were not designed for space applications. 2.SENSORS CHOICEMost of commercial sensors are used for webcam or digital still camera. Sensors choice is a bit difficult as we have many possibilities and as lifetime of new products is very short. Finally we decided to evaluate four different sensors, relatively representatives of elements that we were interested to test: black & white and color sensors, different technologies, and different types of pixels. Here after are the characteristics of the evaluated CMOS sensors: A Bayer filter is used on B2 color sensor as shown on the photo of the chip on Fig. 2-2. As CMOS sensors are “SoC”(System On Chip), outputs of this devices are digital : photons enter and bits come out. So we have to carefully look to what is measured and what is obtained. It is not always an easy job to go back to the raw images at pixel level. 3.ENVIRONMENT TEST PLANA relatively classic test plan was decided. Ionizing doses (obtained by gamma rays) have been applied by step until 15 kRad(Si) for “A” and “B” sensors and 50 kRad(Si) for the “C” sensor. The doses rates were relatively small : between 30 and 40 rad/h. For the “C” sensor we performed measurements immediately after each dose step and 24 hours after the step to try to evaluate the proportion of non generated interface states. During this interval devices were “on” and polarized. For annealing after doses, different protocols where used. For “A” and “C” sensors we applied a normalized 168h @ 100°C annealing. For the “B” sensors we do “isochrones” (see Fig. 3-1.) annealing until 140°C to try to identify activation energy of defects. For the Displacement Damage test we applied on “A” and “B” sensors the following irradiations :
On “C” sensors, we applied :
The annealing procedure was the same as for doses. 4.TEST BENCH FACILITYCNES test benches allows to do classical electro-optic characterizations:
We can also perform spectral characterizations with a spectrometer present on the bench. This allowed us to make relative spectral response measurements and to see if spectral characteristics have shifted. The spectrum is spread in the horizontal side of the device and the response is obtained by meaning all the lines of the same column. Finally we use two lasers (532nm and 632nm) to make the spatial-spectral calibration. The test bench is presented in Fig. 4-1. For dark signal measurement, devices are finely regulated in temperature to minimize measurement drifts. Every measurement is preceded by the measurement of a witness device to calibrate the test bench. So usually, electro-optical characteristics under illumination are presented after normalization to the witness. 5.IONIZING DOSES RESULTS5.1“A” SensorResults show that essentially dark current was modified (Conversion Factor is quite constant as demonstrated on Fig 5.1-3). It is to note that there is no “rebound” after annealing (see Fig. 5.1-1). This could indicate that the doses rate is small enough to reveal the interface states during the irradiation time. Characteristics under illumination (sensitivity, linearity, PRNU) are similar before and after total ionizing doses. Fig.5.1-4 presents measurements of relative spectral response after irradiation. 5.2“B” SensorAs for “A” sensor, the major change occurs on dark current (Fig. 5.2-1 and 5.2-3). Annealing steps (isochrones steps) show a small rebound in the dark current curve (Fig. 5.2-2) that can be explained by the revelation of some interface states. Fig. 5.2-4 to 5.2-8 give the normalized spectral response behaviors of the B&W Bl devices and of the four colors components of B2 devices. We can note that these spectral responses are not affected by ionizing doses. 5.3“C” SensorWe only made measurements of dark current drift as neither illuminated electro-optical characteristics nor relative spectral response changed on “A” and “B” sensors. It is to note that - even if the results are not presented in the paper - measurements made immediately after doses steps and 24 hours (polarized) after the step are quite similar (-10%). This confirm that with relatively small doses rates, the interface states have the time to be revealed, and no rebound appear after annealing. Annealing shows a significant curing (see Fig. 5.3-1) suggesting that the major contributor to dark signal is due to trapped charges in oxides. 6.DISPLACEMENT DAMAGE RESULTSResults show that only dark signal characteristics seem to change. Electro-optical performances under illumination and relative spectral responses did not change (Fig 6-2 to Fig. 6-6) even for sensors with organic filters (B2). For these sensors we also did an isochrone annealing. In Fig. 6-1, we can observe the mean dark current level evolution versus the NIEL. We also verify (not presented here) the linear dependency of dark current with protons fluency. Fig. 6-2 present the normalized spectral response of the “A” (B&W) devices after protons irradiations. Fig. 6-3 to 6-5 give the normalized spectral response measured for the four colors components of “B2” colors devices. We can note that all these spectral responses are not affected by protons irradiations. 7.COMPARISON AND DISCUSSIONTotal ionizing doses dark current and DSNU evolutions shows that sensors “B” and “C” are much sensible to trapped oxide charges compared to interface state as annealing allows a more or less large curing (see Fig. 7-1). We could compare mean dark current evolution of the 3 types of sensors in physical units (nA/cm2) using the conversion factor measurement. The limited evolution of dark signal of “A” sensor seems very attractive compared to “B” and “C”. We could also compare the degradation induced by ionizing doses for each type of sensor (Fig. 7-2). The evolution is around 2 nA/cm2/krad for “B” & “C” sensors at low doses. Note that “A” sensor seems to be slightly impacted compare to the others (<1 nA/cm2/krad). As the major degradation on sensors is on dark signal, it is also interesting to determine the part of the degradation caused by ionizing doses from one side and by displacement damage from the other side. If we consider Eq. 7-1, we could calculate the ionizing dose deposed by the protons, and then compare the evolution of dark signal versus the ionizing doses deposed by gamma rays and versus the ionizing doses deposed by protons (Fig. 7-3). Eq. 7-1 : Amount of doses deposed by protons. K is function of proton Energy (1,01.10-2 for 10 MeV) Fig. 7-3 shows that for “A” sensor the major contributor on mean dark signal is the doses (deposed by the protons or by the gamma rays) : displacement damage are quite small (for mean current, it is not the same thing for the maximum). For the “B” sensor the (mean) dark current drift has a contribution of doses and a contribution of displacement damage. 8.CONCLUSIONSOur evaluation gives some results on performances evolution of “recent” CMOS imagers. It shows that dark signal is sensible to total ionizing doses and displacement damage. The evolution of the dark current is probably mainly due to trapped oxide charges as a more or less huge cure is observed after annealing. Illuminated characteristics seem to be more or less “radiation proof. Our results confirm also that the use of organic micro-lenses or Bayer color filter is not prohibited anymore from radiations point of view. This could open the way to increase performances of CMOS imager (Sensitivity versus pixel reduction). To complete our evaluation we also realized some “classical” evaluation lines such as latch up, Life Test and Vacuum files which are not presented in this paper. No major problems were encountered. This opens the opportunity to use commercial CMOS imagers (or micro cameras) for some low performances space applications such as appendices deployment verification, robotic vision, … |