9 June 2023 Post-undulator beam measurements with PolariX TDS in SwissFEL
P. Craievich, Z. Geng, F. Marcellini, C. Kittel, S. Reiche, T. Schietinger, G. Wang, E. Prat
Author Affiliations +
Abstract
Radiofrequency (RF) transverse deflection structures (TDSs) are fundamental time-resolved diagnostics in x-ray free-electron lasers. Two x-band TDSs with variable polarization of the deflecting force were recently installed after the undulators of Athos, the soft x-ray beamline of SwissFEL. This contribution summarizes the experience gained over the last few months during the commissioning of the RF system and the measurements made during operations, focusing on the setup of the entire complex RF system, the calibration and the time-resolved measurement that, combined with an energy spectrometer, provides longitudinal phase-space measurements of extreme importance for the commissioning of the complex FEL schemes implemented in the Athos beamline.
Conference Presentation
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
P. Craievich, Z. Geng, F. Marcellini, C. Kittel, S. Reiche, T. Schietinger, G. Wang, and E. Prat "Post-undulator beam measurements with PolariX TDS in SwissFEL", Proc. SPIE 12581, X-Ray Free-Electron Lasers: Advances in Source Development and Instrumentation VI, 1258106 (9 June 2023); https://doi.org/10.1117/12.2665447
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Beam divergence

Polarization

Calibration

Free electron lasers

Beam propagation method

Diagnostics

Electron beams

Back to Top