Presentation + Paper
12 March 2024 A comparison of multichannel singlet oxygen luminescence dosimetry (MSOLD) and singlet oxygen explicit dosimetry (SOED)
Author Affiliations +
Abstract
Direct detection of singlet-state oxygen ([1O2]) is a crucial objective in type II photodynamic therapy (PDT), achievable through the implementation of multispectral singlet oxygen dosimetry (MSOLD). To accurately assess the amount of reactive singlet oxygen, the Singlet Oxygen Explicit Dosimetry (SOED) model was developed, incorporating parameters such as light fluence rate, photosensitizer concentration, and ground-state oxygen concentration. This study focuses on comparing the results obtained from MSOLD and SOED by measuring the singlet oxygen signal via a commercial InGaAs spectrometer and subsequently calculating reactive singlet oxygen based on the SOED theory. A continuous-wave laser emitting at 630nm is employed to excite Protoporphyrin IX (PPIX) in methanol, varying the concentration from 10mg/kg to 100mg/kg. Utilizing the Singular Value Decomposition (SVD) algorithm, the measured singlet oxygen spectrum is fitted to extract the singlet oxygen signal. To simulate clinical PDT scenarios, real-time singlet oxygen spectra are collected over 1200 seconds, employing a 1.5mm diameter optic fiber for signal collection. Ground-state oxygen concentration is measured using a commercial oxygen probe while the laser is inactive, and photosensitizer concentration is assessed via a custom-made contact probe. Additionally, the fluence rate of the laser is measured using an isotropic detector. The Reactive Singlet Oxygen is then calculated using the SOED model, incorporating the photosensitizer concentration, oxygen concentration, and photon fluence rate. Detailed comparisons between MSOLD and SOED results are presented, offering valuable insights into the accuracy and reliability of both methods in quantifying singlet-state oxygen during PDT.
Conference Presentation
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Weibing Yang, Dennis Sourvanos, Baozhu Lu, Hongjing Sun, Madelyn Johnson, Brain C. Wilson, Robert H. Hadfield, and Timothy C. Zhu "A comparison of multichannel singlet oxygen luminescence dosimetry (MSOLD) and singlet oxygen explicit dosimetry (SOED)", Proc. SPIE 12823, Optical Methods for Tumor Treatment and Detection: Mechanisms and Techniques in Photodynamic Therapy XXXII, 1282305 (12 March 2024); https://doi.org/10.1117/12.3003421
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Oxygen

Photodynamic therapy

Dosimetry

Fluorescence

Singular value decomposition

Spectroscopy

Luminescence