Paper
11 August 1995 New interferometric method for measuring refractive index distribution in wedge-shaped GRIN blanks
Ludmila A. Gerasimova
Author Affiliations +
Abstract
A new interferometric method for measuring refractive index distribution in GRIN blanks with shapes deviating from plane-parallel ones is described. It uses a standard double-pass interferometric scheme modified to provide single passing of the beam through the investigated GRIN sample. Four interferograms recorded with one preliminary adjustment of the sample allow to restore the distribution of refractive index in the sample, eliminating errors introduced by imperfectness of the interferometer and of sample surfaces, and wedge shape of the sample. The method does not need information about the thickness and the wedge angle of a blank. Two-dimensional dependence of refractive index in transverse dimensions along the sample surface can be measured with the accuracy better than 1(DOT)10-4.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ludmila A. Gerasimova "New interferometric method for measuring refractive index distribution in wedge-shaped GRIN blanks", Proc. SPIE 2537, Novel Optical Systems Design and Optimization, (11 August 1995); https://doi.org/10.1117/12.216393
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Refractive index

GRIN lenses

Interferometry

Interferometers

Error analysis

Mirrors

Wavefronts

Back to Top