29 October 1981 Criteria For Testing Of Afocal Visual Instruments
G. J. Burton
Author Affiliations +
Proceedings Volume 0274, Assessment of Imaging Systems II; (1981) https://doi.org/10.1117/12.931849
Event: Assessment of Imaging Systems: Visible and Infrared, 1981, Reading, United Kingdom
Abstract
The aim of this paper is to identify possible objective test methods for afocal visual instruments which are relevant to user requirements. The problems associated with testing image quality of such instruments are introduced and discussed. A direct concern in this work is providing quality assurance specifications pertaining to sights of a fixed design but constructed in large production runs, not to small numbers of specially assembled sights. The experimental work is divided into two parts. The original investigation examines the levels of correlation obtainable between existing types of MTF-related image quality specifications and subjective resolution tests. It is demonstrated that greater care must be taken, than hitherto, in choosing appropriate test methods. In addition, very low levels of correlation are obtained between subjective resolution tests and objective MTF-related measures. The discussion of possible reasons leads, naturally, to the new investigation. A well-controlled analytical experiment was devised specifically to test the aspect unique to afocal visual instruments: coherent coupling between the sight and the eye. The investigation attempts to mimic, by subjective means, the variables and conditions relevant to (objective) MTF measurements. This investigation has not yet been completed; but the preliminary results do show, however, that expectations of quantitative agreement between subjective and objective test techniques are not borne out. The comparison fails spectacularly, suggesting that coherent coupling effects represent a major source of discrepancy. Some details are given of current measurements aimed at elucidating the precise factors involved in the optical coupling between an afocal sight and the eye.
© (1981) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. J. Burton "Criteria For Testing Of Afocal Visual Instruments", Proc. SPIE 0274, Assessment of Imaging Systems II, (29 October 1981); https://doi.org/10.1117/12.931849
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Telescopes

Eye

Visualization

Image quality

Imaging systems

Visible radiation

RELATED CONTENT

Diffraction Effects On Infrared-System Performance
Proceedings of SPIE (August 24 1988)
Highly integrated near-to-eye display and gaze tracker
Proceedings of SPIE (May 05 2010)
High-Speed Production Lens Testing
Proceedings of SPIE (October 29 1981)
ISPI a wide field NIR imager for the CTIO...
Proceedings of SPIE (September 30 2004)
Contrast Sensitivity In The Assessment Of Visual Instruments
Proceedings of SPIE (October 29 1981)

Back to Top