Paper
22 November 1996 Considerations for a soft x-ray spectromicroscopy beamline
Barry L. Winn, X. Hao, Chris J. Jacobsen, Janos Kirz, J. Miao, Sue Wirick, Harald Ade, Christopher J. Buckley, Malcolm R. Howells, Steven L. Hulbert, Ian McNulty, Tom Oversluizen
Author Affiliations +
Abstract
The X-1A soft x-ray undulator at the NSLS is the source for our experimental programs in spectromicroscopy. We require both spatial and temporal coherence. Due to the relatively large horizontal divergence of the electron beam in the low (beta) straight section of the x-ray storage ring, it has been possible to split the beam using a scraping mirror into two branches: X-1A used by our program and X-1B used for high resolution spectroscopy. We are now rebuilding the X-1A beamline to provide improved resolving power and essentially linear trade-off between photon rate at the zone plate and resolving power for the soft x-ray spectromicroscopy experiments. This new beamline will exploit both additional floorspace due to the NSLS building expansion and increases in the brightness of the x-ray ring. Our beam will be further split into two separate beamlines, both of which will use toroidal mirrors to focus the source on the monochromator entrance slits horizontally and to focus on the monochromator exit slits vertically. This separation comes at no loss of coherent flux and permits low thermal loading on the optics, since we need little more than the coherent fraction of the beam at the Fresnel zone plate for microfocusing. Because of the small angular acceptance for spatially coherent illumination of the zone plates and the use of an approximately satisfied Rowland condition, our monochromators have sufficient resolving power with fixed exit arms. Experiments can then be placed near the exit slits, with spatial coherence established by the exit slit size. Resolving power will be controlled by adjusting the entrance slit alone with no change of spatial coherence. The zone plates will be overfilled to be less sensitive to beam vibration and drift.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Barry L. Winn, X. Hao, Chris J. Jacobsen, Janos Kirz, J. Miao, Sue Wirick, Harald Ade, Christopher J. Buckley, Malcolm R. Howells, Steven L. Hulbert, Ian McNulty, and Tom Oversluizen "Considerations for a soft x-ray spectromicroscopy beamline", Proc. SPIE 2856, Optics for High-Brightness Synchrotron Radiation Beamlines II, (22 November 1996); https://doi.org/10.1117/12.259854
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Zone plates

Mirrors

X-rays

Spectral resolution

Monochromators

Spatial coherence

Diffraction

RELATED CONTENT

The optical design of the soft x ray self seeding...
Proceedings of SPIE (September 30 2013)
SM-PGM monochromator design for large spectral range
Proceedings of SPIE (November 03 1997)
X ray performance of gratings in the extreme off plane...
Proceedings of SPIE (January 29 2004)
Status Of The Zone Plate Microscope
Proceedings of SPIE (March 24 1982)

Back to Top