Paper
22 May 2003 Pre-ablative high-resolution MRA facilitates electrophysiologic pulmonary vein ablation and reduces fluoroscopy time in patients with paroxysmal atrial fibrillation
Jeremy D. Collins, F. Scott Pereles M.D., David Bello M.D., Timothy Betts M.D., Anish Zachariah, Ryan Kaliney, Gina K. Song M.D., Stephanie M. Shors M.D., James C. Carr M.D., John Paul Finn M.D.
Author Affiliations +
Abstract
Pulmonary MRA generates high-resolution images of the pulmonary veins (PV) and left atrium (LA), permitting characterization of complex PV anatomy, which is useful in electrophysiologic PV catheter ablation, a proven technique for the treatment of paroxysmal atrial fibrillation (PAF). The purpose of this study was to determine if pre-ablative pulmonary MRA with intra-ablative viewing facilitates ablation by reducing fluoroscopy time. We studied the morphology of the LA and PV at 1.5T (Magnetom Sonata, Siemens Medical Solutions, Erlangen Germany) with breath-held gadolinium-enhanced 3D MRA in 7 patients with PAF undergoing PV ablation. Data was volume rendered (VR) on a stereoscopic workstation. PV ostial diameter and cross-sectional area measurements were obtained on multi-planar reformatted (MPR) images. VR datasets were converted into digital movies and were viewed on a laptop computer adjacent to real-time fluoroscopic images. Fluoroscopy times for patients undergoing pre-ablative MPA mapping were compared with a cohort of 22 consecutive patients diagnosed with PAF who underwent catheter ablation without pre-ablative MRA planning. Mean PV ablation fluoroscopic time with MRA planning versus fluoroscopic imaging alone were 84±20 minutes and 114±20 minutes respectively. Pre-ablative MRA planning resulted in a significant mean fluoroscopy time savings of 26% (p<0.05). In patients with PAF undergoing PV ablation, analysis of MRA datasets depicting PV anatomy confirms that there is great variability in anatomy between veins. Pre-ablative 3D PV mapping by MRA greatly facilitates fluoroscopic identification of individual veins and significantly reduces fluoroscopic radiation time.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jeremy D. Collins, F. Scott Pereles M.D., David Bello M.D., Timothy Betts M.D., Anish Zachariah, Ryan Kaliney, Gina K. Song M.D., Stephanie M. Shors M.D., James C. Carr M.D., and John Paul Finn M.D. "Pre-ablative high-resolution MRA facilitates electrophysiologic pulmonary vein ablation and reduces fluoroscopy time in patients with paroxysmal atrial fibrillation", Proc. SPIE 5034, Medical Imaging 2003: Image Perception, Observer Performance, and Technology Assessment, (22 May 2003); https://doi.org/10.1117/12.480098
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photovoltaics

Veins

Fluoroscopy

Atrial fibrillation

3D modeling

Magnetic resonance imaging

3D metrology

Back to Top