6 March 2013 Expanded analysis of occupational dose in interventional and diagnostic fluoroscopy with the use of active dosimeters
R. Bujila, C. Palmgren, A. Omar, A. Fransson
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86683X (2013) https://doi.org/10.1117/12.2007571
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Due to the relatively high occupational doses associated with interventional and diagnostic fluoroscopy procedures it is important to create awareness about and to quantify the radiation environment that medical staff are exposed to. A computer program was developed to analyze dose data collected from a dosimetry system that uses active personal dosimeters to monitor staff dose in real-time, to obtain an expanded analysis of the radiation environment that clinical staff are exposed to, on a procedural basis. The analyses that are made per procedure and staff member include: accumulated dose μSv, maximum and median dose rate mSv/h, the amount of time a staff member has been exposed to radiation compared to the total fluoroscopy time and the percentage of accumulated dose from 3 different dose rate intervals, including < 0.3 mSv/h, 0.3 - 2.6 mSv/h, and < 2.6 mSv/h. The developed computer program was used to analyze dose data collected from the dosimetry system at the Karolinska University Hospital to study the radiation environment that different categories of staff are exposed to during interventional aorta aneurysm treatment procedures. The analyses have provided the ability to know where to concentrate radiation safety training in interventional and diagnostic fluoroscopy and to ensure that operating rooms are equipped with adequate radiation protection (e.g., radiation protection barriers etc.). The developed computer program and dose data collected from the dosimetry system can be appropriated for other radiation environmental studies in diagnostic x-ray imaging.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. Bujila, C. Palmgren, A. Omar, and A. Fransson "Expanded analysis of occupational dose in interventional and diagnostic fluoroscopy with the use of active dosimeters", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86683X (6 March 2013); https://doi.org/10.1117/12.2007571
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Avalanche photodetectors

Software

Fluoroscopy

Diagnostics

Computing systems

Statistical analysis

Imaging systems

RELATED CONTENT


Back to Top