Paper
17 July 2015 Quantification of biofilm thickness using a swept source based optical coherence tomography system
Author Affiliations +
Proceedings Volume 9524, International Conference on Optical and Photonic Engineering (icOPEN 2015); 95242L (2015) https://doi.org/10.1117/12.2190106
Event: International Conference on Optical and Photonic Engineering (icOPEN2015), 2015, Singapore, Singapore
Abstract
Optical coherence tomography (OCT) is a non-invasive, non-contact optical measurement and imaging technique that relies on low coherence interferometry. Apart from bio-imaging applications, the applicability of OCT can be extended to metrological investigations because of the inherent capability of optical interferometry to perform precise measurement with high sensitivity. In this paper, we demonstrate the feasibility of OCT for the measurement of the refractive index and thickness of bacterial biofilm structures grown in a flow cell. In OCT, the depth profiles are constructed by measuring the magnitude and time delay of back reflected light from the scattering sites by means of optical interferometry. The optical distance between scattering points can be obtained by measuring the separation between the point spread functions (PSF) at the respective points in the A-scan data. The refractive index of the biofilm is calculated by measuring the apparent shift in the position of the PSF corresponding to a reference surface, caused by the biofilm growth. In our experiment, the base layer of the flow cell is used as the reference surface. It is observed that the calculated refractive index of the biofilm is close to that of water, and agrees well with the previously reported value. Finally, the physical thickness of the biofilm is calculated by dividing the optical path length by the calculated value of refractive index.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ratheesh Kumar M., Murukeshan V. M., L. K. Seah, and C. Shearwood "Quantification of biofilm thickness using a swept source based optical coherence tomography system", Proc. SPIE 9524, International Conference on Optical and Photonic Engineering (icOPEN 2015), 95242L (17 July 2015); https://doi.org/10.1117/12.2190106
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical coherence tomography

Refractive index

Glasses

Point spread functions

Light scattering

Optical imaging

Data acquisition

RELATED CONTENT


Back to Top