Open Access
10 July 2013 Adaptive row-action inverse solver for fast noise-robust three-dimensional reconstructions in bioluminescence tomography: theory and dual-modality optical/computed tomography in vivo studies
Author Affiliations +
Abstract
A novel approach is presented for obtaining fast robust three-dimensional (3-D) reconstructions of bioluminescent reporters buried deep inside animal subjects from multispectral images of surface bioluminescent photon densities. The proposed method iteratively acts upon the equations relating the multispectral data to the luminescent distribution with high computational efficiency to provide robust 3-D reconstructions. Unlike existing algebraic reconstruction techniques, the proposed method is designed to use adaptive projections that iteratively guide the updates to the solution with improved speed and robustness. Contrary to least-squares reconstruction methods, the proposed technique does not require parameter selection or optimization for optimal performance. Additionally, optimized schemes for thresholding, sampling, and ordering of the bioluminescence tomographic data used by the proposed method are presented. The performance of the proposed approach in reconstructing the shape, volume, flux, and depth of luminescent inclusions is evaluated in a multitude of phantom-based and dual-modality in vivo studies in which calibrated sources are implanted in animal subjects and imaged in a dual-modality optical/computed tomography platform. Statistical analysis of the errors in the depth and flux of the reconstructed inclusions and the convergence time of the proposed method is used to demonstrate its unbiased performance, low error variance, and computational efficiency.
© 2013 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2013/$25.00 © 2013 SPIE
Ali Behrooz, Chaincy Kuo, Heng Xu, and Brad W. Rice "Adaptive row-action inverse solver for fast noise-robust three-dimensional reconstructions in bioluminescence tomography: theory and dual-modality optical/computed tomography in vivo studies," Journal of Biomedical Optics 18(7), 076010 (10 July 2013). https://doi.org/10.1117/1.JBO.18.7.076010
Published: 10 July 2013
Lens.org Logo
CITATIONS
Cited by 15 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Zinc

Copper

In vivo imaging

Bioluminescence

Error analysis

3D image processing

Back to Top