The Dark Energy Spectroscopic Instrument (DESI) is an ongoing spectroscopic survey to measure the dark energy equation of state to unprecedented precision. We describe the DESI Sky Continuum Monitor System, which tracks the night sky brightness as part of a system that dynamically adjusts the spectroscopic exposure time to produce more uniform data quality and to maximize observing efficiency. The DESI dynamic exposure time calculator (ETC) will combine sky brightness measurements from the Sky Monitor with data from the guider system to calculate the exposure time to achieve uniform signal-to-noise ratio (SNR) in the spectra under various observing conditions. The DESI design includes 20 sky fibers, and these are split between two identical Sky Monitor units to provide redundancy. Each Sky Monitor unit uses an SBIG STXL-6303e CCD camera and supports an eight-position filter wheel. Both units have been completed and delivered to the Mayall Telescope at the Kitt Peak National Observatory. Commissioning results show that the Sky Monitor delivers the required performance necessary for the ETC.
The recently commissioned Dark Energy Spectroscopic Instrument (DESI) will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sqdeg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope delivers light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. A consortium of Aix-Marseille University (AMU) and CNRS laboratories (LAM, OHP and CPPM) together with LPNHE (CNRS, IN2P3, Sorbonne Université and Université de Paris) and the WINLIGHT Systems company based in Pertuis (France), were in charge of integrating and validating the performance requirements of the ten full spectrographs, equipped with their cryostats, shutters and other mechanisms. We present a summary of our activity which allowed an efficient validation of the systems in a short-time schedule. We detail the main results. We emphasize the benefits of our approach and also its limitations.
The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.
The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. We will describe the production and manufacturing processes developed for the 5000 fiber positioner robots mounted on the focal plane of the Mayall telescope.
The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. To achieve this goal, it is crucial to guarantee that fiber positioners work properly under the extremes of potential operating conditions, including the full range of temperatures, high speed wind disturbance etc. Thermal testing provides valuable insight into the functionality of the fiber positioners that can be used to help mitigate poor performance at extreme temperatures and wind disturbance test provide guidance to design of ventilation system. Here, we describe the thermal and wind disturbance tests for DESI fiber positioners and how the test results helped improve the robustness of the positioners.
The Dark Energy Spectroscopic Instrument (DESI) is under construction to determine the expansion history of the Universe using the Baryon Acoustic Oscillation technique. Over the life of the experiment DESI will measure the spectra of 35 million galaxies and quasars over 14,000 square degrees out to a redshift of 3.5. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5,000 robotic fiber positioners located at the prime focus. The fibers in turn will feed ten broad-band spectrographs covering the wavelength range from 360nm to 980 nm. Rapid and accurate targeting of the fibers is provided by precision theta-phi robotic fiber positioners. The fiber positioners are manufactured at the University of Michigan. Following assembly each positioner passes through a burn-in and verification sequence. We describe the testing of the positioners and discuss the performance achieved.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.