We present a rapid, portable optical system for label-free detection of COVID-19. Raman spectra from an entire liquid drop of saliva supernatant can be obtained within 6 minutes, and the sample is classified as COVID-19 positive or negative using artificial intelligence (AI).
293 COVID negative and 49 COVID positive saliva supernatant samples were analyzed. Positive samples were from hospitalized patients (non-critical and critical) and non-hospitalized testing clinic volunteers (symptomatic and asymptomatic). Our Raman/AI system has an 82% accuracy detecting people with COVID-19 of any severity with any symptom presentation, and 89% accuracy when detecting COVID-19 in hospitalized patients alone. Rapid label-free analysis of biofluids for viruses could provide a low-cost screening solution that could be adapted to respond to viral mutations. This could be invaluable for future pandemics and for reducing infections in hospitals, care homes and workplaces.