Conjugation of aptamers and their corresponding analytes onto plasmonic nanoparticles mediates the formation of nanoparticle assemblies: molecularly bound nanoclusters that cause a measurable change in the colloid’s optical properties. The optimization of a surface-enhanced Raman spectroscopy (SERS) competitive binding assay utilizing plasmonic “target” and magnetic “probe” nanoparticles for the detection of the toxin bisphenol-A (BPA) is presented. These assay nanoclusters were housed inside three types of optofluidic chips patterned with magnetically activated nickel pads, in either a straight or array pattern. Both Fe2O3 and Fe2CoO4 were compared as potential magnetic cores for the silver-coated probe nanoparticles. We found that the Ag@Fe2O3 particles were, on average, more uniform in size and more stable than Ag@Fe2CoO4, whereas the addition of cobalt significantly improved the collection time of particles. Using Raman mapping of the assay housed within the magnetofluidic chips, it was determined that a 1×5 array of 50 μm square nickel pads provided the most uniform SERS enhancement of the assay (coefficient of variation ∼25%) within the magnetofluidic chip. Additionally, the packaged assay demonstrated the desired response to BPA, verifying the technology’s potential to translate magnetic nanoparticle assays into a user-free optical analysis platform.
A micro- to nanochannel nanoparticle aggregating device that does not require any input energy to organize the particles to a specific location, i.e., no pumps, plugs, heat, or magnets, has been designed and used to characterize the surface-enhanced Raman spectroscopy (SERS) signal from four unique functionalized nanoparticles (gold, silver-gold nanocages, silver nanocubes, and silica-gold nanoshells). The SERS signal was assessed in terms of the peak signal strength from the four different Raman reporter functionalized nanoparticles to determine which nanoparticle had better utility in the channel to provide the most robust platform for a future biological analyte detection device. The innovation used to fabricate the micro- to nanochannel device is described; the TEM images of the nanoparticles are shown; the absorption data for the nanoparticles are given; and the spectral data for the Raman reporter, mercaptobenzoic acid (MBA), are depicted. In the micro- to nanochannel described in this work, 5 μl of 22.3 μM MBA functionalized silver nanocubes were determined to have the strongest SERS enhancement.
Conjugation of oligonucleotides or aptamers and their corresponding analytes onto plasmonic nanoparticles mediates the formation of nanoparticle assemblies: molecularly bound bundles of nanoparticles which cause a measurable change in the colloid’s optical properties. Here, we present further optimization of a “SERS off” competitive binding assay utilizing plasmonic and magnetic nanoparticles for the detection of the toxin bisphenol A (BPA). The assay involves 1) a ‘target’ silver nanoparticle functionalized with a Raman reporter dye and PEGylated BPA-binding DNA aptamers, and 2) a version of the toxin BPA, bisphenol A diglycidyl ether (BADGE), PEGylated and immobilized onto a silver coated magnetic ’probe’ nanoparticle. When mixed, these target and probe nanoparticles cluster into magnetic dimers and trimers and an enhancement in their SERS spectra is observed. Upon introduction of free BPA in its native form, target AgNPs are competitively freed; reversing the nanoparticle assembly and causing the SERS signal to “turn-off” and decrease in response to the competitive binding event. The assay particles were housed inside two types of optofluidic chips containing magnetically active nickel pads, in either a straight or spotted pattern, and both Fe2O3 and Fe2CoO4 were compared as magnetic cores for the silver coated probe nanoparticle. We found that the Ag@ Fe2O3 particles were, on average, more uniform in size and more stable than Ag@ Fe2CoO4, while the addition of cobalt significantly improved the collection time of particles within the magnetic chips. Using 3D Raman mapping, we found that the straight channel design with the Ag@ Fe2O3 particles provided the most uniform nanoparticle organization, while the spotted channel design with Ag@ Fe2CoO4 demonstrated a larger SERS enhancement, and thus a lower limit of detection.
Signal transductions including multiple protein post-translational modifications (PTM), protein-protein interactions (PPI), and protein-nucleic acid interaction (PNI) play critical roles for cell proliferation and differentiation that are directly related to the cancer biology. Traditional methods, like mass spectrometry, immunoprecipitation, fluorescence resonance energy transfer, and fluorescence correlation spectroscopy require a large amount of sample and long processing time. “microchannel for multiple-parameter analysis of proteins in single-complex (mMAPS)”we proposed can reduce the process time and sample volume because this system is composed by microfluidic channels, fluorescence microscopy, and computerized data analysis. In this paper, we will present an automated mMAPS including integrated microfluidic device, automated stage and electrical relay for high-throughput clinical screening. Based on this result, we estimated that this automated detection system will be able to screen approximately 150 patient samples in a 24-hour period, providing a practical application to analyze tissue samples in a clinical setting.
Rapid assessment of radiation exposure to sensitive organs like the gut is extremely important for large populations exposed to ionized radiation, for instance during warfare. Recent results have shown that plasma citrulline levels appear to track gut function after irradiation levels in mice and humans. The current ways to monitor blood citrulline levels are bulky, laborious, time-consuming and expensive methods. Therefore, an optofludic point-of-care (POC) system using surface enhanced Raman spectroscopy to measure plasma citrulline as a marker for radiation exposure that overcomes the above issues is being developed.
As a first step toward development of this system four colloidal nanoparticles, spherical gold, silver cubes, silica-gold nanoshells, and silver-gold nanocages have been analyzed for use in the POC system. Transmission electron microscopy (TEM) images have been taken of each nanoparticle to visualize the morphology of the nanoparticles, which is vital for SERS. Ultraviolet-visible (UV/Vis) spectroscopy was also collected to verify the extinction spectra for each nanoparticle was in resonance with the excitation wavelength. The nanoparticles were functionalized with mercaptobenzoic acid (MBA), a Raman reporter molecule, and SERS spectra were collected to determine which has better utility in a novel micro-to-nanochannel. The data showed that the silver nanocubes have a larger enhancement factor than the gold nanospheres, nanoshells, or nanocages. Currently, these nanocubes are being functionalized with the citulline for assessing the concentration sensitivity and dynamic range for ultimate use as a marker for radiation.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.