Paper
1 January 1998 Comet assay, cloning assay, and light and electron microscopy on one preselected cell
Karsten Koenig, Hartmut Oehring, Karl-Juergen Halbhuber, Ursula Fiedler, Eckhard Bauer, Karl-Otto Greulich
Author Affiliations +
Abstract
In order to perform long-term studies up to one week on a preselected single cell after micromanipulation (e.g. UVA and NIR microbeam exposure) in comparison with non-treated neighbor cells (control cells) we applied a variety of single cell diagnostic techniques and developed a special comet assay for single preselected cells. For that purpose adherent cells were grown in low concentrations and maintained in special sterile centimeter-sized glass cell chambers. After preselection, a single cell was marked by means of diamond-produced circles on the outer cell chamber window. During exposure to microbeams, NADH-attributed autofluorescence of the chosen cell was detected by fluorescence imaging and spectroscopy. In addition, cell morphology was video-monitored (formation of pseudopodia, membrane blebbing,...). Maintaining the microchamber in the incubator, the irradiated cell was examined 24 h later for cell division (clone formation) and modifications in autofluorescence and morphology (including daughter cells). In the case that no division occurred the vitality of the light-exposed cell and of the control cells were probed by intranuclear propidium iodide accumulation. After fixation, either electron microscopy or single cell gel electrophoresis (comet assay) was performed. To monitor comet formation indicating photoinduced DNA damage in the preselected single cell in comparison with the non-exposed neighbor cells the chamber was filled with low-melting gel and lysis solution and exposed to an electric field. In contrast to the conventional comet assay, where only randomly chosen cells of a suspension are investigated, the novel optimized electrophoresis technique should enhance the possibilities of DNA damage detection to a true single (preselected) cell level. The single cell techniques applied to UVA microexposed Chinese hamster ovary cells (364 nm, 1 mW, 3.5 W/cm2) revealed significant cell damage for J/cm2 fluences such as modifications of intracellular redox state, impaired cell division, formation of giant cells and cell shrinking, swelling of mitochondria and loss of cristae as well as DNA damage.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Karsten Koenig, Hartmut Oehring, Karl-Juergen Halbhuber, Ursula Fiedler, Eckhard Bauer, and Karl-Otto Greulich "Comet assay, cloning assay, and light and electron microscopy on one preselected cell", Proc. SPIE 3199, Biomedical Systems and Technologies II, (1 January 1998); https://doi.org/10.1117/12.301123
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Comets

Luminescence

Electron microscopy

Imaging spectroscopy

Microscopy

Near infrared

Diagnostics

Back to Top