Open Access
22 November 2012 Reflectance imaging of the human retina at 810 nm does not suffice to optimize the parameters of hydrodynamic rebalancing laser treatment
Filippo M. Piffaretti, Jean-Pierre Ballini, Roberto Perotti, Matthieu Zellweger, Edoardo Vezzola, Michel Sickenberg, Georges A. Wagnières
Author Affiliations +
Abstract
The hydrodynamic rebalancing laser (HRL) procedure is an ophthalmic therapy based on the administration of subthreshold infrared (810 nm) laser light to selected areas on the retina to treat various retina diseases. Heterogeneities of tissue response are observed, including undesired retinal damages. Variations of tissue absorbance were hypothesized to cause this uneven response. Irradiation parameters (diameter=100  μm; power=1  W; irradiation time: 50 to 200 ms), location and tissue response were studied in 16 patients (20 eyes, 2535 laser spots) to discover any correlation between tissue response and normalized fundus reflectance at 810 nm. The results demonstrate a complex relationship between some pathologies and occurrences of retinal damage, but no clear correlation. One possible reason is that the resolution of reflectance images is insufficient to see "small" (40 μm or less) absorption centers, particularly deep-seated ones. Additionally, tissue parameters other than variations of the fundus optical absorption influence heat diffusion and temperature increases. Monitoring or individualizing the light dose in HRL therapy, or any similar infrared diode laser-based therapy will require more sophisticated technologies, including imaging the retina's reflectance with an improved resolution, as well as refined methods to detect complex correlations between retinal damage and specific pathologies.
© 2012 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2012/$25.00 © 2012 SPIE
Filippo M. Piffaretti, Jean-Pierre Ballini, Roberto Perotti, Matthieu Zellweger, Edoardo Vezzola, Michel Sickenberg, and Georges A. Wagnières "Reflectance imaging of the human retina at 810 nm does not suffice to optimize the parameters of hydrodynamic rebalancing laser treatment," Journal of Biomedical Optics 17(11), 116027 (22 November 2012). https://doi.org/10.1117/1.JBO.17.11.116027
Published: 22 November 2012
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reflectivity

Laser therapeutics

Retina

Eye

Laser tissue interaction

Absorption

Tissues