|
1.IntroductionThe trans-follicular route for drug administration has gained a lot of attention in recent years, mainly driven by the advent of nanoparticle-based delivery systems facilitating absorption into hair follicles. Current research efforts span a broad field of different applications ranging from cosmetic products for acne treatment up to transcutaneous vaccination.1–3 Different aspects contribute to the attractiveness of the hair follicle for drug delivery. Anatomically, the hair follicle embodies an invagination of the epidermis resulting in an increased surface area available for penetration and absorption of drugs surrounded by numerous blood capillaries facilitating systemic absorption. Furthermore, the presence of antigen presenting cells as, for instance, Langerhans cells bears the potential to provoke an immune response.3,4 In addition, the hair follicle was found to provide a long-term drug reservoir for up to 10 days.5 The development of novel drug delivery systems for trans-follicular delivery necessitates a suitable model for in vitro absorption and penetration studies into the hair follicle. For skin absorption and percutaneous penetration testing, porcine skin has been evaluated as a valuable in vitro model.6 Yet, for trans-follicular drug delivery it is important to know whether explicitly porcine hair follicles are suitable for simulating the human hair follicle. As far as the anatomical comparison, both follicles show an inner and outer root sheath, a sebaceous gland associated with the hair follicle and sweat glands in the dermal layer.7,8 The thickness of the stratum corneum and the viable epidermis as well as density and follicle diameter of the hairs were found to be similar.7 By using the skin sandwich method, it was demonstrated that porcine hair follicle absorption of different solutes varying in their physicochemical properties matches previously accumulated absorption data into the human hair follicle.9 Furthermore, in contrast to human skin, porcine ear cartilage prevents contraction of tensile fibers and subsequent closure of the hair follicles, thus corroborating the applicability of a porcine model. To analyze the extent of follicular drug penetration, the state of the art procedure is cyanoacrylate skin surface stripping. This technique implies the application of superglue to a predetermined skin area covered by a tape strip. Upon polymerization of the glue, the tape strip is quickly peeled off, removing corneocytes, the stratum corneum and the follicular cast.10 These biopsies are subsequently extracted and the content of penetrated drugs is analytically quantified. Several studies have already shown evidence that percutaneous absorption in pig skin is equivalent to that in human skin.7,11 However, because the sebum within the hair follicle forms the release medium for drugs delivered via the trans-follicular route, the equivalency of human and porcine sebum is quite important. The different components that constitute sebum in humans, rats, mice and hamsters have been assessed showing that it is gerenally composed of triglycerides, sterol- or wax-esters, diol-diesters, free sterols, and free fatty acids. However, only human sebum contains squalene.9,12 Unfortunately, according to our knowledge there is no literature about the composition of porcine sebum. Even though the porcine hair follicle is widely used as an in vitro model simulating the human follicle, an all-encompassing comparison in terms of chemical composition has not been performed so far. A suitable technique for a chemically selective and nondestructive analysis of such samples is confocal Raman microscopy. Besides a spectroscopic analysis of the individual chemical composition, confocal Raman microscopy offers the possibility of sample mapping, thus facilitating the visualization of spatially resolved component distribution. So far, confocal Raman microscopy was used for qualitative follow-up of substances into skin in vivo13 as well as in vitro.14,15 Furthermore, Raman microscopy has proven its suitability to map substance distribution on the skin surface.16 Recently, studies visualized human hair composition, gaining information about protein secondary structure and disulfide cross-links.17 In this study, we apply confocal Raman spectroscopy to evaluate the chemical similarity of human and porcine hair follicles. For this purpose, we compare the spectral properties of the four main follicle-associated components—hair, sebum, dermis and follicular epidermis. Furthermore, confocal Raman microscopy is used to image follicle cross sections, visualizing the component distribution. Finally, the novel complementary analytical approach of confocal Raman and optical profilometry is used to visualize cyanoacrylate biopsies of hair follicles in three dimensions. 2.Materials and Methods2.1.MaterialsTesafilm® kristall-klar (Tesa, , cut to pieces of ) was purchased from Tesa AG, Hamburg, Germany. UHU superglue (UHU, blitzschnell Pipette) was provided by UHU GmbH & Co, KG, Bühl/Baden, Germany. Mayer’s haematoxylin was obtained from Carl Roth Co. KG, Karlsruhe, Germany. 2.2.Porcine SkinFresh pig ears were obtained from Emil Färber GmbH & Co. KG, Zweibrücken, Germany. The ears were excised before brewing and shipped immediately to the lab. After rinsing with water, they were inspected for evident skin abrasions prior to use. Only healthy-looking skin was selected for the experiments. 2.3.Human SkinFresh human skin for the in vitro experiment was obtained from plastic surgery of female Caucasian patients from the department of Plastic and Hand Surgery, Caritaskrankenhaus, Lebach, Germany. The study included thigh skin from a female donor, 48 years old, previously consented. Immediately upon arrival of the skin, the subcutaneous adipose tissue was removed with a scalpel and the skin was cut into pieces of , wrapped in aluminum foil and stored in polyethylene bags at until use. The study was approved by the ethical commission of Saarland, Germany (Aerztekammer des Saarlandes, 204/08). 2.4.Cross-Sections of Hair FollicleTo get a cross section of a hair follicle, a biopsy of a sample was cut out of the intact frozen thigh skin using a scalpel and cross-sections with a thickness of 15 μm were cut using a cryomicrotome (MEV Cryostat, Slee, Mainz, Germany). Nuclear staining was performed using Mayer’s haematoxylin. The optical microscope images were taken using a Zeiss AXIO Scope A1 light microscope (Carl Zeiss Microscopy GmbH, Oberkochen, Germany) equipped with a digital camera (AxioCam ERc 5 s). Images were edited and labeled using the software Zen lite 2011 (Carl Zeiss Microscopy GmbH, Oberkochen, Germany). 2.5.Cyanoacrylate Skin Surface StrippingCyanoacrylate skin surface biopsies were taken by applying a drop of superglue on a predetermined and precleansed location of the excised pig ear, immediately followed by application of a tape strip on top.10,18 After polymerization of the glue (15 min), this tape was quickly removed along with the content of the hair follicle. For analysis the biopsies were fixed upside down on glass slides, leaving the follicles sticking up. 2.6.Confocal Raman MicroscopyFor confocal Raman microscopic evaluation, cross-sections and cyanacrylate biopsies were placed on calcium fluoride slides. Measurements were performed using a Witec alpha (WITec GmbH, Ulm, Germany). The excitation source was a diode laser with an emitting wavelength of 785 nm. Laser power was adjusted to 50 mW before the objective, which was found to be harmless to biological tissue. Microscopic images were obtained with a objective (Epiplan Neofluar N.A. 0.5, Zeiss, Germany). Raman single spectra and maps were recorded with a objective (Epiplan Neofluar N.A. 0.8, Zeiss, Germany). A confocal pinhole of 100 μm rejected signals from out-of-focus regions. Raman spectra were recorded in the range of 400 to with a spectral resolution of . For single spectra, three measurements over a 10-s integration time were averaged. Raman mapping was performed by collecting data for 10 s every 5 μm in and directions. The data were processed using WITec Project Plus software (WITec GmbH, Ulm, Germany). After cosmic ray removal, the spectral baseline was corrected using a polynomic fit. All spectra were normalized to the most intense peak (1430 to representing .19 2.7.Optical ProfilometrySurface topography measurements were performed with a True Surface Microscopy sensor integrated in a Witec alpha confocal Raman microscope (WITec GmbH, Ulm, Germany). The sensor can resolve an elevation difference of 3 mm, with an accuracy of 1 μm. Data points were recorded every 5 μm in and directions, generating a lateral resolution equivalent to Raman mapping. 3.Results and Discussion3.1.Comparison of Porcine and Human Hair FolliclesPorcine ear skin represents a commonly used model for analysis of drug penetration into hair follicles. However, besides anatomical and physiological similarity one major aspect for the applicability of such a model is the chemical equivalence with the simulated site in the human body. Thus, in order to verify the suitability of porcine follicles as an in vitro substitute for human follicles, a comparison of the composition of major chemical components is performed by confocal Raman spectroscopy. Optical and dimensional similarity of porcine and human hair follicles and the adhering tissue are depicted as microscopic sections in Fig. 1(a) and 1(b), respectively. The hair (blue cross), follicular epidermis (yellow cross), deeper skin layers (green cross), and the sebaceous gland (red cross) are clearly visible in the individual cross-sections. To evaluate the spectral comparability, Raman spectra were obtained from the four regions of interest marked by the colored crosses. Raman spectra recorded from porcine and human dermis (green), hair (blue), follicular epidermis (yellow) and a sebaceous gland (red) are depicted in Fig. 1(c) and 1(d), respectively (colored figures available online only). The follicular epidermis spectrum is composed of unspecific bands representing protein at around (aromatic amino acids), at and at (amide I) with keratin as the main component.19 The dermis spectrum is additionally characterized by two double peaks at 815 to and 920 to . This pattern is representative for collagen, which is localized in the dermis in significantly higher quantities than in other tissue regions.20 Human and porcine hair reveal a prominent peak at specific for cross-links, which appear in high content in keratotic tissues like horn, hoof, and hair.17,21 To evaluate the recorded spectra of human and porcine hair follicle components regarding similarity, a statistically meaningful method is necessary. Therefore, spectral subtraction and calculation of the area under the curve (AUC) of the resulting graphs are performed. As references, three spectra for each component from different positions were subtracted from each other. This generates graphs specifying the internal spectral variability for each individual component. Figure 2(a) depicts these graphs for hair in blue, follicular epidermis in yellow, dermis in green, and sebum in red (colored figures available online only). The confidence interval (CI) of spectral similarity for each individual component is subsequently calculated based on the absolute AUC of these graphs deriving mean and standard deviation. Finally, component spectra of human and porcine follicles are subtracted from each other and AUC of the resulting graph was determined. The calculated AUC of these graphs as well as the confidence interval for spectral similarity are listed in Fig. 2(b). The graph representing the hair states a significantly higher AUC than the reference. However, a direct comparison of the subtracted spectra, as shown in Fig. 2(c) reveals no major discrepancies but high noise. Moreover, the internal variability of the reference measurement for hair is rather small, explaining the detected difference. For follicular epidermis and dermis, no significant difference is exposed. Noteworthy is the high variability in epidermal spectra. This can be explained by the different follicular epidermal layers. To assure robustness of our method, epidermal spectra were taken from different layers. Paying special attention to the sebum as the potential release medium for drug carrier systems, no significant difference in Raman spectra is noted between human and porcine sebum. However, the direct spectral comparison displayed in Fig. 2(d) exhibits a slight heartbeat shaped discrepancy between 1050 and . Even though not significantly different, this result indicates a peak shift in the initial spectra from mainly trans conformational stretch vibrations in porcine to more random conformations in human sebum. The characteristic peak shift from 1060 to of the skeletal vibrations confirms these findings.22 Other small discrepancies are intensity related and hint at negligible concentration differences of sebum components. Finally, the inter-individual variability of human and porcine skin composition was not taken into account since a vast number of individuals need to be tested to gain valid results. Yet, Raman spectroscopy has proven its value to compare chemical composition of all main hair follicle components and indicates chemical similarity of the different tissues and sebum in particular. 3.2.Raman Mapping of Follicle Cross-SectionsFor visualization of different tissue components staining procedures represent the most common technique. Figure 3(a) shows a porcine hair follicle cross-section after haematoxylin nuclear staining. A clear differentiation between follicular epidermis, dermis, and hair is possible. The location of a sebaceous gland can be assumed (red arrow) but the sebum remains undetectable. Raman mapping allows the discrimination of different components according to their Raman spectra without staining, visualizing the component distribution. An unstained microscopic section of a porcine hair follicle is displayed in Fig. 3(b). Raman spectra are recorded from the area indicated by the red rectangle in the image with a step size of 5 μm. After processing the spectral data with multivariant analysis algorithms to identify the component distribution, a false color Raman image is obtained allocating each picture pixel with a color representing similar Raman spectra [Fig. 3(c)]. In this binary method, all spots with spectra representing the dermis are shown in green, follicular epidermis in yellow, hair in blue, and sebum in red. In this image, each pixel is explicitly assigned to a component. Figure 3(d) depicts the same area after further data processing. This approach displays intensity differences and allows displaying multiple components simultaneously in one pixel. This procedure facilitates a more detailed depiction of the component distribution. A close comparison of Fig. 3(c) and 3(d) reveals the advantages of this more sophisticated method. For instance, traces of sebum (red) can be identified on top of the hair (blue), which is not visible by the binary approach (colored figures available online only). The sebum is mainly located in the sebaceous gland and along the hair shaft. Slight traces of sebum remaining on the hair are considered artifacts generated by the cutting procedure. The Raman map successfully allows insight into the follicle's constitution not feasible by conventional microscopy. Raman microscopy enables visualization and characterization of the follicle’s most important components without any labeling or staining. Furthermore, the methodology bares a high potential to track penetration of drugs and drug delivery systems in the follicular tissue. 3.3.Visualization of Cyanoacrylate Skin Surface BiopsiesCyanoacrylate skin surface stripping represents the most common analytical technique to analyze the penetration behavior of drug delivery systems into hair follicles. Removing the hair and the follicular cast as a cyanoacrylate biopsy allows extraction and quantification of penetrated drugs. However, the quality and extent of follicle removal cannot be analyzed with this procedure. Microscopy analysis of a follicle biopsy reveals limitations, as conventional light microscopy only gains information from one focal plane at a time. Figure 4(a) and 4(b) displays two light microscopic pictures obtained from two different focal planes of a porcine cyanoacrylate biopsy visualizing this problem. The biopsy tape is turned upside down with the excised hairs pointing upwards. Only fractions of the hairs can be assessed this way. To evaluate the complete follicle, a three-dimensional analytical approach is necessary. A versatile method for analysis of structured samples is optical profilometry. The basic principle relies on the effect of chromatic aberration. With a set of hyperchromatic lenses good mapping-point capabilities are associated with a high chromatic error. Thus, white light which is focused through this lens assembly is split in its different colors, assigning different focal lengths to each color. While detecting the reflected light through a confocal pinhole, a topography map can be generated as displayed in Fig. 4(c). By applying the aforementioned methodology, the complete cyanoacrylate biopsy with the excised hairs can be visualized [Fig. 4(d)]. In a second step, this method allows overlaying the sample surface topography map with Raman spectroscopic information. After determining the surface structure, Raman spectra can be obtained from the exact sample surface eliminating weak signal intensity caused by out of focus effects. This enables Raman mapping of highly structured specimen. In this study, the technique was utilized to image a hair follicle obtained from a cyanoacrylate surface biopsy. Figure 5(a) shows a microscopic picture of a single hair bulb. In the area indicated by the red rectangle, the surface structure was assessed by optical profilometry. The resulting topography map of the follicle is presented in Fig. 5(b). The individual Raman spectra of the chemical components within a hair bulb are displayed in Fig. 5(c). Overlaying the surface topography map with the spatially resolved Raman spectral information results in a three-dimensional component distribution map of the follicle [Fig. 5(d)]. The false color image displays hair in blue, sebum in red and epidermal structures in yellow, thus matching the color of the component spectra displayed in Fig. 5(c). The image depicts an intact follicular epidermis shell enclosing the hair root. Traces of sebum can be found outside the shell, indicating the location of the sebaceous gland. An enhanced sebum presence at the bottom might indicate thinner layers of follicular epidermis at the lower hair bulb. The analytical evidence of the extraction of complete hair bulbs by cyanoacrylate skin surface biopsies corroborates the suitability of this technique for quantification of drugs within the hair follicle. Furthermore, the novel combination of optical profilometry and confocal Raman microscopy proves its value for the evaluation of skin biopsies and indicates its potential for other analytical approaches. 4.ConclusionConfocal Raman microscopy proves its enormous potential for nondestructive, chemically selective analysis and evaluation of trans-follicular drug delivery. The comparison and evaluation of human and porcine hair follicles based on their individual Raman spectra successfully indicates their similarity. Besides component distribution analysis within cross-sections, the novel combination of optical profilometry and confocal Raman microscopy allows three-dimensional chemically resolved imaging of cyanoacrylate skin surface biopsies. These results indicate the potential of this analytical approach to visualize penetration behavior of drug delivery systems in follicles as well as for noninvasive depth profiling as a future perspective. AcknowledgmentsWe thank L. Muijs for technical support and K.-H. Kostka from Caritas Hospital, Lebach, Germany, for providing human skin. ReferencesL. MuR. L. Sprando,
“Application of nanotechnology in cosmetics,”
Pharm. Res., 27
(8), 1746
–1749
(2010). http://dx.doi.org/10.1007/s11095-010-0139-1 PHREEB 0724-8741 Google Scholar
A. A. DateB. NaikM. S. Nagarsenker,
“Novel drug delivery systems: potential in improving topical delivery of antiacne agents,”
Skin Pharmacol. Phys., 19
(1), 2
–16
(2006). http://dx.doi.org/10.1159/000089138 SPPKE6 1660-5527 Google Scholar
S. HansenC. M. Lehr,
“Nanoparticles for transcutaneous vaccination,”
Microb. Biotechnol., 5
(2), 156
–167
(2012). http://dx.doi.org/10.1111/mbt.2012.5.issue-2 MBIIB2 1751-7915 Google Scholar
V. M. MeidanM. C. BonnerB. B. Michniak,
“Transfollicular drug delivery—is it a reality?,”
Int. J. Pharm., 306
(1–2), 1
–14
(2005). http://dx.doi.org/10.1016/j.ijpharm.2005.09.025 IJPHDE 0378-5173 Google Scholar
J. Lademannet al.,
“Hair follicles—a long-term reservoir for drug delivery,”
Skin Pharmacol. Phys., 19
(4), 232
–236
(2006). http://dx.doi.org/10.1159/000093119 SPPKE6 1660-5527 Google Scholar
Y. FrumG. M. EcclestonV. M. Meidan,
“In-vitro permeation of drugs into porcine hair follicles: is it quantitatively equivalent to permeation into human hair follicles?,”
J. Pharm. Pharmacol., 60
(2), 145
–151
(2008). http://dx.doi.org/10.1211/jpp.60.2.0002 JPPMAB 0022-3573 Google Scholar
U. Jacobi,
“Porcine ear skin: an in vitro model for human skin,”
Skin Res. Technol., 13
(1), 19
–24
(2007). http://dx.doi.org/10.1111/srt.2007.13.issue-1 SRTEFN 0909-752X Google Scholar
F. H. Sakamotoet al.,
“Porphyrin distribution after topical aminolevulinic acid in a novel porcine model of sebaceous skin,”
Lasers Surg. Med., 41
(2), 154
–160
(2009). http://dx.doi.org/10.1002/lsm.v41:2 LSMEDI 0196-8092 Google Scholar
G. W. Luet al.,
“Comparison of artificial sebum with human and hamster sebum samples,”
Int. J. Pharm., 367
(1–2), 37
–43
(2009). http://dx.doi.org/10.1016/j.ijpharm.2008.09.025 IJPHDE 0378-5173 Google Scholar
A. Teichmannet al.,
“Differential stripping: determination of the amount of topically applied substances penetrated into the hair follicles,”
J. Invest. Dermatol., 125
(2), 264
–269
(2005). http://dx.doi.org/10.1111/j.0022-202X.2005.23779.x JIDEAE 0022-202X Google Scholar
R. L. BronaughR. F. StewartE. R. Congdon,
“Methods for in vitro percutaneous absorption studies. II. Animal models for human skin,”
Toxicol. Appl. Pharmacol., 62
(3), 481
–488
(1982). http://dx.doi.org/10.1016/0041-008X(82)90149-1 TXAPA9 0041-008X Google Scholar
A. C. Laueret al.,
“Targeted delivery to the pilosebaceous unit via liposomes,”
Adv. Drug Deliv. Rev., 18
(3), 311
–324
(1996). http://dx.doi.org/10.1016/0169-409X(95)00089-P ADDREP 0169-409X Google Scholar
P. J. Casperset al.,
“In vivo confocal Raman microspectroscopy of the skin: noninvasive determination of molecular concentration profiles,”
J. Invest. Dermatol., 116
(3), 434
–442
(2001). http://dx.doi.org/10.1046/j.1523-1747.2001.01258.x JIDEAE 0022-202X Google Scholar
A. Tfayliet al.,
“Follow-up of drug permeation through excised human skin with confocal Raman microspectroscopy,”
Eur. Biophys. J., 36
(8), 1049
–1058
(2007). http://dx.doi.org/10.1007/s00249-007-0191-x EBJOE8 0175-7571 Google Scholar
G. ZhangC. R. FlachR. Mendelsohn,
“Tracking the dephosphorylation of resveratrol triphosphate in skin by confocal Raman microscopy,”
J. Control Release, 123
(2), 141
–147
(2007). http://dx.doi.org/10.1016/j.jconrel.2007.08.001 JCREEC 0168-3659 Google Scholar
C. AdlhartW. Baschong,
“Surface distribution and depths profiling of particulate organic UV absorbers by Raman imaging and tape stripping,”
Int. J. Cosmetic Sci., 33
(6), 527
–534
(2011). http://dx.doi.org/10.1111/ics.2011.33.issue-6 IJCMDW 0142-5463 Google Scholar
G. ZhangL. SenakD. J. Moore,
“Measuring changes in chemistry, composition, and molecular structure within hair fibers by infrared and Raman spectroscopic imaging,”
J. Biomed. Opt., 16
(5), 056009
(2011). http://dx.doi.org/10.1117/1.3580286 JBOPFO 1083-3668 Google Scholar
A. FinlayR. Marks,
“Determination of corticoid concentration profiles in stratum corneum using the skin surface biopsy technique,”
Br. J. Derm., 107
(33),
(1982). BJDEAZ 1365-2133 Google Scholar
B. W. BarryH. G. M. EdwardsA. C. Williams,
“Fourier-transform Raman and Infrared vibrational study of human skin—assignment of spectral bands,”
J. Raman Spectrosc., 23
(11), 641
–645
(1992). http://dx.doi.org/10.1002/jrs.v23:11 JRSPAF 0377-0486 Google Scholar
L. Silveiraet al.,
“Discriminating model for diagnosis of basal cell carcinoma and melanoma in vitro based on the Raman spectra of selected biochemicals,”
J. Biomed. Opt., 17
(7), 077003
(2012). http://dx.doi.org/10.1117/1.JBO.17.7.077003 JBOPFO 1083-3668 Google Scholar
H. G. M. EdwardsD. E. HuntM. G. Sibley,
“FT-Raman spectroscopic study of keratotic materials: Horn, hoof and tortoiseshell,”
Spectrochim. Acta. A, 54
(5), 745
–757
(1998). http://dx.doi.org/10.1016/S1386-1425(98)00013-4 SAMCAS 1386-1425 Google Scholar
G. Socrates, Infrared and Raman Characteristic Group Frequencies: Tables and Charts, Wiley & Sons, West Sussex
(2004). Google Scholar
|