Open Access
13 October 2017 Spatiotemporal image correlation analysis of blood flow in branched vessel networks of zebrafish embryos
Nicolo G. Ceffa, Ilaria Cesana, Maddalena Collini, Laura D’Alfonso, Silvia Carra, Franco Cotelli, Laura Sironi, Giuseppe Chirico
Author Affiliations +
Abstract
Ramification of blood circulation is relevant in a number of physiological and pathological conditions. The oxygen exchange occurs largely in the capillary bed, and the cancer progression is closely linked to the angiogenesis around the tumor mass. Optical microscopy has made impressive improvements in in vivo imaging and dynamic studies based on correlation analysis of time stacks of images. Here, we develop and test advanced methods that allow mapping the flow fields in branched vessel networks at the resolution of 10 to 20  μm. The methods, based on the application of spatiotemporal image correlation spectroscopy and its extension to cross-correlation analysis, are applied here to the case of early stage embryos of zebrafish.

1.

Introduction

Flow regulation of physiological activity is a wide field of life sciences.1 Both in human beings and artificial environments, three-dimensional (3-D) structures such as cellular aggregates leading to organoids or bacterial colonies are often immersed in an aqueous fluid in motion and subjected to hydrodynamic forces.2 The progression of a wide number of diseases is affected directly by blood circulation. An important example is cancer3 and its metastases. Some diseases produce an impaired blood supply to organs.4,5 These different fields of research share a common feature. The fluid circulation presents a pulsatile, occasionally irregular, flow with ramifications in evolution, and it requires high spatial and time resolution to be studied.

The focus of the field of angiogenesis research has, in recent years, shifted toward the analysis of network formation mechanisms, also connected to tissue engineering,6 as well as the study of vessel maturation and remodeling processes.7 This has led to the discovery of vascular guidance and networking molecules as well as the identification of vessel maturation-regulating molecules, such as the angiopoietins and the platelet-derived growth factors.8 In this field, medical research often exploits small animal models such as zebrafish embryos9 and juvenile transparent fishes10,11 for pilot in vivo studies. In addition, the advances of microfluidics are greatly influencing several fields of microbiology, providing new tools to investigate processes developing under flow, such as bacterial biofilm formation.12

Our aim is, therefore, to devise methods to map quantitatively the flow field at the branching point along a vessel network. We describe and test an algorithm able to quantify in a user-independent way the dominant flow in a branched network of sprouting vessels. To show real-field applications, we apply these algorithms on the zebrafish embryo model by following the motion of red blood cells in the embryo’s blood (contrary to hemolymph, which is the fluid circulating in arthropods). Our method is based on the use of spatiotemporal image correlation spectroscopy (STICS) analysis coupled to single plane illumination microscopy (SPIM).13 This strategy allows us to reach flow field mapping with the spatial resolution of a few micrometers and to single out different periodic components, as typically found in hemodynamics.9,14 A powerful alternative technique, Doppler optical coherence tomography, has been applied15,16 to map the flow field in branched microfluidic devices in 3-D (10-×10-×10-μm3 resolution). These works, however, were focused on the study of turbulence in large channels (mm in size) and at larger flow speeds (few mm/s) than typically found in hemodynamics. Cross-correlation analysis was already applied on a dual or multispot level for the detailed analysis of the flow in straight microfluidic capillaries and in straight vessels in vivo.9 STICS analysis was applied to wide field images of blood flow in vessels as a validation for intrasurgical applications.17 We extend here the original STICS algorithm18 to the cross correlation over different fields of view chosen along the flow direction to increase the dynamic range for the measurement of the flow speed and use a multicomponent analysis of the correlation maps that allows us to exploit the amplitude of the correlation map to evaluate the flow fractionation at the branching points. The present analysis is limited here to two-dimensional (2-D) flows that can be analyzed simply by following the displacement of the cross-correlation map with the lag time. However, our STICS-based approach can be extended to a 3-D reconstruction of the flow field by following the cross-correlation amplitude decay with the lag time.

2.

Experimental Section

2.1.

Single Plane Illumination Microscopy Setup

The SPIM setup18,14 employs an argon−krypton laser (Melles Griot), expanded 14 and focused into the back aperture of an illumination objective (Olympus, UMPLFLN 10XW, 10×, NA=0.3, working distance=3.5  mm). The fluorescence emission is selected by a bandpass filter and is detected by an EMCCD detector (Cascade II, Photometrics) through an Olympus MPLFLN objective (20×, NA=0.5, working distance=3.5  mm; see Fig. 1 for details). The maximum acquisition rate was 4  ms/frame on reduced regions of 40×250  μm2.

Fig. 1

(a) Photo and (b) sketch of the SPIM setup. The source is an argon laser (514-nm emission line). A beam expander (1, focal lengths 25 and 50 mm) expands the incoming laser beam. A variable rectangular slit (2) creates a thin vertical aperture in the optical path. The cylindrical lens (3) is positioned at the focal length (50 mm) from the slit. The beam reducer (4, focal lengths 50 and 25 mm) reduces the incoming laser beam to fill the objective back aperture. The excitation objective (5) is an Olympus, water dipping, 10×, 0.3 NA. (6) The positioning system (for sample rotation and 3-D translation) and the sample holder. The detection objective (7) is an Olympus, water dipping, 20×, 0.5 NA. The tube lens (8) has focal length 150 mm. The detector (9) is an EMCCD detector (Cascade II—photometrics).

JBO_22_10_106008_f001.png

2.2.

Zebrafish Embryos

The measurements were done on embryos of zebrafish (3 days postfertilization, d.p.f.). We used the transgenic line mitfaw2/w2; roya9/a9; Tg(kdrl:EGFP)S843; Tg-(gata1:dsRed)sd2, carrying green-labeled epithelium (EGFP) and red-labeled (dsRed) red blood cells.19 The zebrafish embryos were anesthetized20 with tricaine [40  mg/L tricaine(ethyl 3-aminobenzene methansulfonate, Sigma–Aldrich Corporation, St. Louis, Missouri)], positioned in a 2-mm diameter fluorinated ethylene propylene tube (FT2X3, Adtech Polymer Engineering, Frampton Mansell, UK), and then immersed in a water cell.14,21

2.3.

Spatiotemporal Image Correlation Spectroscopy Images Analysis

The STICS images were computed on a time stack of M images S={Ij}j=0,,M taken at M times spaced by δt ranging typically from 13 to 19 ms (corresponding to 74 to 52  frames/s of the EMCCD, the fastest rates compatible with the chosen field of view). We take the SPIM plane as the xy plane. We assume that the flow velocity lies in this plane and is v=(vx,vy). Each image has a size of X×Y  pixels. The image autocorrelation function was computed on the fluctuation matrices obtained by subtracting pixel by pixel the average signal Ik(x,y)k=k=1MIk(x,y)/M to the content of each image of the stack, δIj(x,y)=Ij(x,y)Ik(x,y)k, by the FFT algorithm as follows:

Eq. (1)

G(ξ,η;kδt)=j=0MkFFT1[FFT(δIj)FFT*(δIj+k)]/(Mk).

Each image of the time stack was padded with zeros up to double its size before performing the FFT.

On each correlation image, corresponding to the lag time τ, we automatically selected the position (ξmax,ηmax) of the maximum by fitting the image to a 2-D Gaussian profile. The amplitude of the STICS function was derived from the amplitude of the Gaussian fit function, subtracted for the possible background.

Even though the morphological images are available, we do not want to presume any a priori knowledge of the flow direction. We have then simply computed the STICS image on rectangular regions of interest (ROIs) aligned with the axes of the image as it is acquired. To evaluate the components of the flow velocity in the SPIM plane, we follow the position of the STICS image with the lag time over at least 5 to 10 lag time points, up to a lag time τfit. We have checked that the condition to recover the STICS amplitude is that the ROI size is at least SROI2vxyτfit. A flow of the order 400  μm/s and τfit40  ms corresponds to a size of 16  μm, or at least 20 pixels. This is our spatial limitation in the reconstruction of the field flow.

3.

Results and Discussion

3.1.

Spatiotemporal Image Correlation Spectroscopy Allows to Follow the Flow Along Curved Vessels

We want to devise methods to map the blood flow in tiny branched capillaries. The flow should be characterized in terms of direction and amplitude of the velocity, and we will need to evaluate the flow branching ratio at the ramifications along the network. The rationale of the methods that we are describing is to autocorrelate and cross correlate in space and time stacks of images acquired through a wide field SPIM. In general, we could also map the velocity field by tracking, and then averaging, many trajectories of individual red blood cells. This is not always feasible, for example, when the vessel morphology cannot already be singled out from the images (initial angiogenesis) or the heart pulsation affects the flow, such as in arteries. STICS offers the advantage of directly providing an average flow map in which the heart pulsation effect is averaged out. With STICS, we obtain from a time stack of images a series of autocorrelation maps [Eq. (1)], G(ξ,η;τ), function of the lag time τ. For a uniform drift, the map assumes the shape of a 2-D quasi-Gaussian13,14 function whose maximum occurs at the position rmax=(ξmax,ηmax), measured with respect to the origin of the autocorrelation map and it is a function of τ. Here, we want to exploit the possibility of following both the position and amplitude of the autocorrelation map maximum as a measure of the flow velocity and relative amount of cells taking either of the arms of a branching point. We will then extend this concept to cross correlation of different ROIs in the field of view.

We first assess the problem to reconstruct the flow along a curved vessel independent of possible ramifications. We assume that flow is occurring mainly in the SPIM plane and analyze the time stacks of images according to the STICS algorithm on an ROI (rectangular in shape) chosen in such a way to encompass a small (40  μm) tract of the vessel. The particular anatomy of the zebrafish embryo justifies our assumption. We took care to orientate the embryo in such a way to image in the same light sheet (<12  μm) both major vessels of the embryo. It is known (see, for example, the repository of image22) from the anatomy of the embryo that most of the branching occurs in the same sagittal plane.

We first evaluate, at different positions along the putative vessel axis of the STICS image at increasing lag times and fix the lag time at the maximum value, τfit, for which the maximum rmax=(ξmax,ηmax) of the STICS image lies within the STICS image by at least 5 to 6 pixels. The average velocity of the cells is obtained as v=(ξmax/τfit,ηmax/τfit).14,23,24 The speed is computed, by assuming nonconstrained motion, as dmax=ξmax2+ηmax2.

We need to find a compromise between the finesse of the spatial reconstruction of the flow, the computation time, and the spatial resolution of the STICS image. The latter depends on the brightness of the tracers. In our hands, for red blood cells in living embryos, the minimum displacement of the STICS maximum for which the corresponding velocity uncertainty is smaller than 15% is |rmax|4  pixels (that is 3.2  μm in the sample plane). The lower the signal/noise is, the larger the minimum value of |rmax| is and the coarser the reconstructed flow map is.

Once the ROI size and the fitting lag time have been chosen, the algorithm computes sequentially a set of STICS maps, updating at each step the investigation of ROI with a rigid translation along the vector T=α(ξmax,ηmax). The choice of small propagation factor α<1 allows oversampling of the flow map. We typically adopt α=0.5. A flow line can be built by assigning each flow velocity vector to the center of the corresponding ROI and by representing it with the Quiver python class.25 As can be seen from Fig. 2(a), we can follow the blood flow on a wide field of view (750×750  μm2) with a good resolution, 5 to 10  μm [Figs. 2(c) and 2(d)].

Fig. 2

Evaluation of the red blood cells flow in zebrafish embryo (3 dpf) vessels based on STICS maps from ROIs of (14×14)  pixels (pixel size=2.9  μm). All the flow analyses have been done with propagation factor α=0.5. (a) A wide field picture (256×256  pixels=742×742  μm2) of blood circulation in the abdomen of the embryo. The flow field is reported in four linear tracts of the vessel network as thin arrows whose length is proportional to the speed. At two branching points, the dominant and marginal flow components are reported as green and red filled arrows, respectively. (b) The STICS map for the vessel branching point marked by a dotted white box in (a), at lag time τ=311  ms. (c and d) Zoomed images on one intersomitic vessel in which the trajectories computed from nine different starting points have been reported together with the average flow curve (see text). (e) The flow speed along the reconstructed average flow (green) line and the adjacent (blue) line reported in (c).

JBO_22_10_106008_f002.png

When approaching a branch in the vessel network, the STICS image assumes a double component character [see Fig. 2(b)]. At each step along the path (i.e., on each ROI), we evaluate the relative amplitude of the two peaks and displace the ROI along the direction that corresponds to the most relevant component (according to the maximum of each component detected in the STICS image). In this way, starting from two different points along the vessel network, we are able to evaluate the flow velocity even at the branching points [Fig. 2(a)] and follow it along the individual arms [Figs. 2(c) and 2(d)]. We observed a dependence of the resulting trajectory on the evolution parameter α. We have found that for values α0.5 of the evolution parameter, the flow trajectories closely follow the vessel axis, which can be measured from the morphological image [Fig. 2(a)]. There is still a dependence on the position of the starting point (the center of the first ROI of the sequence) along the putative cross section of the vessel, which is shown in Figs. 2(c) and 2(d) (different discontinuous colored lines). However, the trajectories coalesce on a common path that we have selected by averaging the points that correspond to the position of the individual flow lines on each cross section of the vessel (at steps of 20  μm). The resulting line, reported as a thick semitransparent green line in Figs. 2(b) and 2(c), can be considered the common flow path in the selected vessel. There is no appreciable dependence of the amplitude of the flow speed on the starting point of the trajectory, which can be judged from the plot of the flow speed along two flow lines as shown in Fig. 2(e). This is to be expected since, here, we are tracking red blood cells that are approximately the size of the capillary diameter.

3.2.

Spatiotemporal Image Correlation Spectroscopy Allows Estimation of Flow Branching Ratios at the Vessel Ramifications

The application of the STICS algorithm on a ROI that encompasses a ramification of the vessel network, such as in the black rectangle of Fig. 3(a), results in correlation images, in which two components can be singled out [Fig. 3(b)]. These components can be ascribed to the cells that take either of the two branches. The rapidity of their displacement from the center of the correlation image, rmax(1)=[ξmax(1),ηmax(1)] and rmax(2)=[ξmax(2),ηmax(2)], as a function of the lag times is the measure of the flow direction and the flow speed for cells flowing in each arm. The direction of the velocity vector follows very well the morphology of the vessel ramification, which can be judged from the superposition of the correlation images with the morphological images [Fig. 3(b)]. To this purpose, the correlation images shown in Fig. 3(b) have been inverted by a central symmetry with respect to the center of the correlation space.

Fig. 3

Analysis of the flow ramification at branching points. (a) Morphological image taken on a zebrafish embryo (3 dpf) obtained as the standard deviation projection of the time stack of images used for the STICS analysis. (b) STICS maps computed on the ROI selected in (a) (black rectangle) for increasing lag time, from 164 to 348 ms from left to right and from top to bottom (flow speed coded by a “jet” LUT; morphological images superimposed in light blue). (c) Linear fit of position of the maximum of the STICS images as a function of the lag time. Open (blue) symbols refer to the prevalent component in each STICS image. Open (green) symbols refer to the marginal component (visible for lag times τ170  ms). The linear fit to the data (dashed lines, same color code) gives velocities v1=55±1.5  μm/s and v2=69±3  μm/s for the prevalent and the marginal components, respectively. (d) The Gaussian fitting of the STICS map (lag time=348  ms) together with the profile plots along the ξ and η axes.

JBO_22_10_106008_f003.png

In the correlation maps [Fig. 3(b)], one peak was found to always be larger in magnitude irrespective of the lag time. Moreover, the standard deviation projection image (each pixel contains the standard deviation value found through the time stack) showed very similar signals on the two arms, which indicates that the emission of the individual red blood cells passing through the two arms is very similar. We assume, therefore, that the maximum amplitude of the two correlation components is proportional to the number of red blood cells flowing in one or the other ramification of the vessel branching. For example, as shown in Fig. 3(d), the brightest component of the STICS map corresponds to the red blood cells flowing upward, amounting to 66%±1% of the overall amplitude. The marginal component represents cells flowing from left to right, amounting to 34%±1% of the overall amplitude. The marginal component can be singled out with a reasonable signal/noise ratio (10%) only for lag times τ170  ms. Two values of the flow speed can be computed from the linear fit of the displacements of the maxima of each component as a function of the lag time, as shown in Fig. 3(c): we measure v1=55±1.5  μm/s and v2=69±3  μm/s for the prevalent and the marginal components, respectively. We find then that the marginal component is slightly faster than the prevalent one. This corresponds quite well to the observation that the left–right vessel arm is visibly larger [see Fig. 3(a)] than the bottom-up arm and the fact that the vessels are approximately the size of the red blood cells diameter. It must be noticed that the algorithm for the computation of the flow velocity used here is customized to the case of right-angle crossing between vessels as in Fig. 3(a) (box). Since the flow is constrained to occur along the vessel axis, the displacement of the maximum of the autocorrelation map may, in general, not be along a line passing through the center of the map. In this case, we should compute the flow speed along the vessel axis through the incremental algorithm |rmax(τ+δτ)rmax(τ)|=|v|δτ.

3.3.

Spatiotemporal Cross-Correlation Analysis Enhance Mapping Features

The possibility of spatially mapping the flow relies on the choice of a small ROI on which we apply the spatiotemporal correlation algorithm. The space resolution of the reconstructed flow depends on the size of the ROI (half of its linear size=0.5×SROI). However, a second key parameter for obtaining high-precision flow speed estimations is the max tracer speed (K) inside the investigation ROI. If we assume that at least five lag time points are needed to linearly fit the relation between the displacement |rmax| and the lag time, K can be estimated from the ROI size (SROI) and the CCD frame rate (fps) as K=SROI×fps/5. In the experiments shown in Figs. 1 and 2, fps=74  frames/s and SROI=16  μm and we compute K240  μm/s. If we had larger speed values, we should increase the ROI size, losing then in spatial resolution of the flow mapping. Moreover, if the flow is not aligned with the ROI axes, we would need to increase the ROI size in both the ξ and η directions. This would increase substantially the computation time.

To solve these issues, we propose to adopt an approach consisting of two-stage analysis:

  • 1. perform a first STICS on an ROI with a small lag time to evaluate the flow direction and

  • 2. rigidly translate the ROI of half the size of the original ROI in the flow direction detected at step 1 and perform a spatiotemporal cross correlation between the original and the translated ROI [see Fig. 4(a)].

Fig. 4

Cross-correlation spatiotemporal analysis. (a) The time average of the stack of images. The light and dark gray rectangular boxes are the original and translated ROI, respectively. The white arrow indicates the translation vector. (b) Three autocorrelation images computed on the original ROI for lag times τ=18.2, 36.4, and 54.6 ms. The white arrow indicates in each STICS image the displacement vector rmax=(ξmax,ηmax). (c) The spatiotemporal cross-correlation maps between the original and translated ROIs for absolute lag times τ=18.2, 54.6, and 91 ms. The light green arrow indicates in each cross-correlation image the relative displacement vector rmax=(ξmax,ηmax). (d) The plot of the displacement dmax=ξmax2+ηmax2 as a function of the absolute lag time τ (blue color) and dmax=(ξmax)2+(ηmax)2 as a function of the reduced lag time, ττ0 (green color, τ0=18  ms). The dashed line is the best linear fit to the data and corresponds to the speed v=380±9  μm/s.

JBO_22_10_106008_f004.png

In this way, we can increase the dynamic range of the speeds that can be detected. A flow speed almost 4 times larger than in Fig. 3 can be measured on the vessel reported in Fig. 4(a) with 3% accuracy at 20-μm size resolution (SROI=20  μm). At the same time, we are able to keep the computational costs at the same level as the original autocorrelation algorithm. The details of the algorithm can be gained by comparing Fig. 4(b) (STICS correlation) with Fig. 4(c) (STICCS, cross correlation). We evaluate the flow velocity on the cross-correlation images by translating the correlation frame of reference (ξ,η) at the position (ξ0,η0) at which the cross-correlation peak is first detected and the lag time τ axis to the corresponding lag time, τ0 [see Fig. 4(c)]. The two components of the flow velocity can then be evaluated as the inverse of slope of ξξ0 and ηη0 [the corresponding vector is reported as a white arrow in Fig. 4(c)] as a function of ττ0. This estimate is in very close agreement with the one obtained on the autocorrelation images, which can be judged from Fig. 4(d) (open and filled symbols).

We notice that the analysis presented here is limited to 2-D flows. We could extend it to 3-D flows by following, in addition to the position of the correlation map in the correlation space, the decay with the lag time of its amplitude. The main limitation in this case could be the computation time, more than the acquisition time. In fact, we would work out the information about the out-of-plane motion from the amplitude decay of the cross correlation computed on the time stack of images of a single light sheet. This possibility is currently under investigation in our laboratory.

4.

Conclusions

We have devised and tested correlation and cross-correlation algorithms, specifically designed for SPIM, which allow the analysis of blood flow in branched vessels. This involves the computation of the spatiotemporal correlation (STICS) and cross-correlation (STICCS) images and the analysis of the resulting maps in terms of multiple components. From the relative amplitudes of different components of the STICS map, we assign the prevalent flow direction at branching points and we are able to follow the flow at the ramification, also measuring the flow speed. The application of cross-correlation spatiotemporal methods on two different ROIs on the stacks of images allows the enhancement of the dynamic range of the flow speed measurements and mapping the flow in extended vessel networks with 5 to 10  μm resolution. An example of the resulting flow map reconstruction on two consecutive branching points can be seen in Fig. 2(a). These algorithms could be a great help in analyzing a huge amount of data collected in vivo in the field of developmental biology or in vitro in the setup of vascularized microincubators for tissue engineering.

Disclosures

The authors have no relevant financial interests in this article and no potential conflicts of interest to disclose.

Acknowledgments

This work was supported by the Academic Funding Unimib 2016 (G.C. and L.S.).

References

1. 

D. J. Duncker and R. J. Bache, “Regulation of coronary blood flow during exercise,” Physiol. Rev., 88 1009 –1086 (2008). http://dx.doi.org/10.1152/physrev.00045.2006 PHREA7 0031-9333 Google Scholar

2. 

L. Hall-Stoodley, J. W. Costerton and P. Stoodley, “Bacterial biofilms: from the natural environment to infectious diseases,” Nat. Rev. Microbiol., 2 (2), 95 –108 (2004). http://dx.doi.org/10.1038/nrmicro821 1740-1526 Google Scholar

3. 

S. Alexander et al., “Dynamic imaging of cancer growth and invasion: a modified skin-fold chamber model,” Histochem. Cell Biol., 130 1147 –1154 (2008). http://dx.doi.org/10.1007/s00418-008-0529-1 Google Scholar

4. 

P. Carmeliet, “Angiogenesis in health and disease,” Nat. Med., 9 653 –660 (2003). http://dx.doi.org/10.1038/nm0603-653 1078-8956 Google Scholar

5. 

L. Sironi et al., “In vivo flow mapping in complex vessel networks by single image correlation,” Sci. Rep., 4 7341 (2014). http://dx.doi.org/10.1038/srep07341 SRCEC3 2045-2322 Google Scholar

6. 

B. Zhang et al., “Biodegradable scaffold with built-in vasculature for organ-on-a-chip engineering and direct surgical anastomosis,” Nat. Mater., 15 (6), 669 –678 (2016). http://dx.doi.org/10.1038/nmat4570 Google Scholar

7. 

D. Ribatti and E. Crivellato, “Sprouting angiogenesis,” a reappraisal,” Dev. Biol., 372 (2), 157 –165 (2012). http://dx.doi.org/10.1016/j.ydbio.2012.09.018 DEBIAO 0012-1606 Google Scholar

8. 

C. Korn and H. G. Augustin, “Mechanisms of vessel pruning and regression,” Dev. Cell Rev., 34 5 –17 (2015). http://dx.doi.org/10.1016/j.devcel.2015.06.004 Google Scholar

9. 

P. Pozzi et al., “Electron multiplying charge-coupled device-based fluorescence cross-correlation spectroscopy for blood velocimetry on Zebrafish embryos,” J. Biomed. Opt., 19 (6), 067007 (2014). http://dx.doi.org/10.1117/1.JBO.19.6.067007 JBOPFO 1083-3668 Google Scholar

10. 

R. M. White et al., “Transparent adult Zebrafish as a tool for in vivo transplantation analysis,” Cell Stem Cell, 2 183 –189 (2008). http://dx.doi.org/10.1016/j.stem.2007.11.002 Google Scholar

11. 

L. Fieramonti et al., “Quantitative measurement of blood velocity in Zebrafish with optical vector field tomography,” J. Biophotonics, 8 (1–2), 52 –59 (2015). http://dx.doi.org/10.1002/jbio.201300162 Google Scholar

12. 

J. Bruchmann, “Multi-channel microfluidic biosensor platform applied for online monitoring and screening of biofilm formation and activity,” PLoS One, 10 e0117300 (2015). http://dx.doi.org/10.1371/journal.pone.0117300 POLNCL 1932-6203 Google Scholar

13. 

B. Hebert et al., “Spatiotemporal image correlation spectroscopy (STICS) theory, verification, and application to protein velocity mapping in living CHO cells,” Biophys. J., 88 3601 –3614 (2005). Google Scholar

14. 

C. A. Marquezin et al., “Image cross-correlation analysis of time varying flows,” Anal. Chem., 88 7115 –7122 (2016). http://dx.doi.org/10.1021/acs.analchem.6b01143 ANCHAM 0003-2700 Google Scholar

15. 

M. Bonesi et al., “Study of flow dynamics in complex vessels using Doppler optical coherence tomography,” Meas. Sci. Technol., 18 3279 –3286 (2007). http://dx.doi.org/10.1088/0957-0233/18/11/003 MSTCEP 0957-0233 Google Scholar

16. 

M. Bonesi et al., “Turbulence monitoring with Doppler optical coherence tomography,” Laser Phys. Lett., 4 304 –307 (2007). http://dx.doi.org/10.1002/lapl.200610098 1612-2011 Google Scholar

17. 

M. Rossow, W. W. Mantulin and E. Gratton, “Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels,” J. Biomed. Opt., 14 024014 (2009). http://dx.doi.org/10.1117/1.3088203 JBOPFO 1083-3668 Google Scholar

18. 

P. G. Pitrone et al., “OpenSPIM: an open-access light-sheet microscopy platform,” Nat. Methods, 10 598 –599 (2013). http://dx.doi.org/10.1038/nmeth.2507 1548-7091 Google Scholar

19. 

N. D. Lawson and B. M. Weinstein, “In vivo imaging of embryonic vascular development using transgenic Zebrafish,” Dev. Biol., 248 (2), 307 –318 (2002). http://dx.doi.org/10.1006/dbio.2002.0711 DEBIAO 0012-1606 Google Scholar

20. 

M. A. Akimenko et al., “Differential induction of four MSX homeobox genes during fin development and regeneration in Zebrafish,” Development, 121 (2), 347 –357 (1995). Google Scholar

21. 

A. Bassi et al., “In vivo label-free three-dimensional imaging of Zebrafish vasculature with optical projection tomography,” J. Biomed. Opt., 16 (10), 100502 (2011). http://dx.doi.org/10.1117/1.3640808 JBOPFO 1083-3668 Google Scholar

22. 

“Zebrafish Information Network (ZFIN),” (2017) https://zfin.org/zf_info/anatomy.html October ). 2017). Google Scholar

23. 

J. W. Krieger et al., “Imaging fluorescence (cross-) correlation spectroscopy in live cells and organisms,” Nat. Methods, 10 1948 –1974 (2015). http://dx.doi.org/10.1038/nprot.2015.100 1548-7091 Google Scholar

24. 

M. Bouzin et al., “An intermittent-model Fourier-space analysis of the intracellular motion of gold nanostars by scattering image correlation,” Biophys. J., 109 2246 –2258 (2015). http://dx.doi.org/10.1016/j.bpj.2015.10.025 BIOJAU 0006-3495 Google Scholar

25. 

J. Hunter et al., “The Matplotlib development team,” (2017) https://matplotlib.org/contents.html July ). 2017). Google Scholar

Biography

Nicolo G. Ceffa received his master’s degree in physics from the Università degli Studi di Milano-Bicocca in 2014 and is currently a PhD student in applied physics in the physics department of this university. His research activity focuses on the use of optical microscopy and correlation techniques to investigate both in vivo and in vitro microfluidic systems, in particular, internal motions in artificial liposomes and hemodynamics studies in complex vessel networks.

Ilaria Cesana received her master’s degree in physics from the Università degli Studi di Milano-Bicocca in March 2017. Her thesis was on construction and characterization of an OpenSPIM microscope used for hemodynamics investigation of model organisms, specifically zebrafish embryos (Casper).

Maddalena Collini received her PhD in physics in 1992 and is currently a professor of applied physics at the Università degli Studi di Milano-Bicocca. Her current interests involve the application of optical microscopy (super-resolution and nonlinear excitation) and image correlation techniques to the investigation of biological systems, especially metal nanoparticle uptake and transport inside cells and complex environments.

Laura D’Alfonso has been an associate professor in applied physics at the Università di Milano-Bicocca since 2014. Her research has focused on molecular biophysics, applying spectroscopic techniques to study the structural and dynamic properties of proteins, by combining experimental and theoretical-simulative approaches. She has experience in time-resolved fluorescence and advanced fluorescence techniques employing nonlinear excitation to perform high spatial and temporal resolution imaging and correlative studies, with applications in cells, tissues, and in vivo on model organisms.

Silvia Carra obtained her PhD in cellular and molecular biology from the Università degli Studi di Milano in 2007. She focused her research on developmental biology, cardiovascular development, and genes involved in human diseases using zebrafish (Danio rerio) as a model system. Currently, she works as a research collaborator for IRCCS Istituto Auxologico Italiano on neuroendocrine tumors using zebrafish as an animal model.

Franco Cotelli obtained his Laurea degree in biological sciences from the University of Milano. He is a professor of developmental biology at the University of Milano and PI of the Zebrafish Laboratory at the biosciences department. Since the 1990s, he has used the zebrafish model to study vertebrate development and genes involved in human diseases (nervous, cardiovascular, and hematopoietic systems).

Laura Sironi received her PhD in physics from the Università degli Studi di Milano-Bicocca in 2011 and is currently a research fellow in applied physics in the physics department of this university. She has a background in in vivo nonlinear microscopy and advanced spectroscopic methods for biological and medical applications. Her research also focuses on the development of image correlation spectroscopy techniques devoted to the study of the hemodynamics in model and complex organisms and nanoparticles–cells interaction.

Giuseppe Chirico is a professor of physics at the Department of Physics, University of Milano Bicocca, Milano, Italy. After receiving his doctorate in physics in 1990, he worked at the European Molecular Biology Laboratory (Grenoble, France), the German Cancer Research Center (DKFZ, Heidelberg, Germany) and the Laboratory for Fluorescence Dynamics (LFD, University of Illinois at Urbana-Champaign). He employs biophotonics for the study of the structure and dynamics of cells in vivo.

© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE) 1083-3668/2017/$25.00 © 2017 SPIE
Nicolo G. Ceffa, Ilaria Cesana, Maddalena Collini, Laura D’Alfonso, Silvia Carra, Franco Cotelli, Laura Sironi, and Giuseppe Chirico "Spatiotemporal image correlation analysis of blood flow in branched vessel networks of zebrafish embryos," Journal of Biomedical Optics 22(10), 106008 (13 October 2017). https://doi.org/10.1117/1.JBO.22.10.106008
Received: 17 July 2017; Accepted: 26 September 2017; Published: 13 October 2017
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image analysis

Blood circulation

Blood

Imaging spectroscopy

Capillaries

In vivo imaging

Objectives

Back to Top