The enhanced x-ray timing and polarimetry mission (eXTP) is a flagship observatory for x-ray timing, spectroscopy and polarimetry developed by an international consortium. Thanks to its very large collecting area, good spectral resolution and unprecedented polarimetry capabilities, eXTP will explore the properties of matter and the propagation of light in the most extreme conditions found in the universe. eXTP will, in addition, be a powerful x-ray observatory. The mission will continuously monitor the x-ray sky, and will enable multi-wavelength and multi-messenger studies. The mission is currently in phase B, which will be completed in the middle of 2022.
The Follow-up X-ray Telescope (FXT), a key payload onboard the Einstein Probe sallite (EP), is equipped with a Wolter-I x-ray focusing mirror system. We introduce the principle of such a mirror system and analyze the influence of the mirror gap in the multishell nested mirror of the FXT on the effective area, stray-light ratio, and vignetting. To ensure that no occlusion occurs within adjacent shells and minimize stray-light ratio, the size of the gap is set to a optimized value for corresponding shell. We finished a design of a 54-shell mirror system according to these results. The optical performance of the design was then simulated using a Monte Carlo algorithm and the ray-tracing principle. The simulation shows that the effective area is 414.5 ± 0.2 cm2 at 1.25 keV (considering the spider), and the field of view is 64 arcmin in diameter. These parameters meet the optical requirements of the FXT.
The Einstein Probe (EP) is an X-ray astronomical mission mainly devoting to time-domain astronomy. There are two main scientific payloads onboard EP, the Wide Field X-ray Telescope (WXT) based on the lobster eye optics and the Follow-up X-ray Telescope (FXT). FXT contains two Wolter-1 mirrors with a pnCCD detector on each focus. The total effective area is about 600 cm2 and the energy range is 0.3-10 keV. The pnCCD detector cooled by a pulse tube cooler enables high-resolution spectroscopy and imaging combined with excellent time resolution. It will also have several working modes with time resolution ranging from tens of microseconds to 50 milliseconds. Currently, the FXT is in its qualification model phase. The mirror assemblies (STM and TCM) as well as the pnCCD EM module have been manufactured and tested.
The Medium Energy X-ray Telescope (ME), covering 5-30 keV, is one of the three main payloads of the Hard X-ray Modulation Telescope (HXMT). ME adopts an array of Si-PIN detectors. The detection area of one pixel is 56.25 mm2 , and the total detection area is 952 cm2 . The ME has a large active area while the pixel size is smaller. So the front-end electronics and forming electronics are realized by Application Specific Integrated Circuit (ASIC) chips. In this paper, we will describe the matching design of ME Si-PIN detector and ASIC, and the performance of the design. The energy response, temperature response, and dead time of a Two-Pixels Si-PIN detectors with the simplest readout electronics which is similar with ME, were tested on the Max Planck Institute for Extraterrestrial Physics PANTER X-ray test facility at Neuried by Munchen (Germany). The overall performance is quite similar to what was expected.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.