The Gemini Planet Imager 2.0 (GPI 2.0) is an upgrade to the original GPI, an instrument for directly imaging exoplanet systems, which is being moved to the Gemini North telescope atop Mauna Kea, Hawaii. Major changes involve improved coronagraph designs and upgrading the adaptive optics (AO) system with a new pyramid wavefront sensor (PWFS). The addition of these new components require revised models for evaluating the performance and understanding the limitations of the system. This in turn helps us inform the broader GPI 2.0 science goals. We run end-to-end AO simulations, to assess the performance of GPI 2.0 AO under typical atmospheric conditions on Mauna Kea. We use these simulations to help us determine operating parameters such as the limiting stellar magnitude, maximum Strehl ratio, and the contrast achieved by the joint AO-coronagraph system before speckle-suppression. This information will be used to predict the science performance on a range of targets and design observing strategies.
The Gemini Planet Imager (GPI) is a high-contrast imaging instrument designed to directly detect and characterise young, Jupiter-mass exoplanets. After six years of operation at the Gemini South Telescope in Chile, the instrument is being upgraded and moved to the Gemini North Telescope in Hawaii as GPI 2.0. Several improvements have been made to the adaptive optics (AO) system as part of this upgrade. This includes replacing the current Shack-Hartmann wavefront sensor with a pyramid wavefront sensor (PWFS) and a custom EMCCD. These changes will increase GPI’s sky coverage by accessing fainter targets, improving corrections on fainter stars and allowing faster and ultra-low latency operations on brighter targets. The PWFS subsystem was independently built and tested to verify its performance before being integrated into the GPI 2.0 instrument. This paper will present the pre-integration performance test results, including pupil image quality, throughput and linearity without modulation.
The Gemini Planet Imager (GPI) is a dedicated high-contrast imaging facility instrument. After six years, GPI has helped establish that the occurrence rate of Jovian planets peaks near the snow. GPI 2.0 is expected to achieve deeper contrasts, especially at small inner working angles, to extend GPI’s operating range to fainter stars, and to broaden its scientific capabilities. GPI shipped from Gemini South in 2022 and is undergoing an upgrade as part of a relocation to Gemini North. We present the status of the upgrades including replacing the current wavefront sensor with an EMCCD-based pyramid wavefront sensor, adding a broadband low spectral resolution prism, new apodized-pupil Lyot coronagraph designs, upgrades of the calibration wavefront sensor and increased queue operability. Further we discuss the progress of reintegrating these components into the new system and the expected performance improvements in the context of GPI 2.0’s enhanced science capabilities.
Polarimetric observations can provide important information on many astrophysical phenomena beyond that available via conventional imaging and spectroscopy alone. As a first step toward providing Gemini North instrument support for polarimetric observations, an instrument upgrade program is currently under way to bring one of the GPOL polarization modulator units (GPOL-N) into operation in concert with NIRI at Gemini North (GN) to provide an IR imaging polarimetry in the visiting instrument mode. Featuring three deployable trays that accommodate swappable, rotatable polarizing waveplates and calibration polarizers, GPOL is designed to facilitate polarimetric observations over the opticalinfrared wavelength range of 0.3 – 5 μm. When installed on the telescope, GPOL is physically situated inside the Acquisition and Guidance (A&G) unit, and is designed to work in concert with bottom port instruments containing an oninstrument Wollaston prism, such as NIRI. We present here an overview of the functional characteristics of GPOL and the current status of the GPOL+NIRI commissioning project. Following control board and software updates, the GPOL-N unit is currently undergoing further testing as a prelude to refurbishment. We also briefly discuss subsequent Gemini North polarimetric instrumentation plans, which include the possible future commissioning of a visitor mode that combines GPOL with the GNIRS multifunction spectrograph to provide NIR spectropolarimetry, and polarimetric imaging via the GPI 2.0 instrument.
IGRINS-2 is a high-resolution, near-infrared spectrograph developed by Korea Astronomy and Space Science Institute (KASI) for Gemini Observatory as a new facility instrument. It provides spectral resolving power of ~45,000 and a simultaneous wavelength coverage of 1.49-2.46 μm. IGRINS-2 is an improved version of IGRINS (Immersion GRating INfrared Spectrometer) with minor optical and mechanical design changes, new detector controllers, and operating software to be fully integrated into Gemini operating systems. Since the project began in early 2020, project key milestones including assembly and pre-delivery performance verification were completed, and delivered to Gemini North in early September, 2023. After the successful post-delivery verification and telescope integration, the first light spectra were acquired in October 2023. We present design changes and upgrades made to IGRINS-2 from the original IGRINS, assembly and alignment procedures, and verification of the instrument requirements. We also report the preliminary results of the system performance tests.
MAROON-X is a fiber-fed, optical EPRV spectrograph at the 8-m Gemini North Telescope on Mauna Kea, Hawai’i. MAROON-X was commissioned as a visiting instrument in December 2019 and is in regular use since May 2020. Originally designed for RV observations of M-dwarfs, the instrument is used for a broad range of exoplanet and stellar science cases and has transitioned to be the second-most requested instrument on Gemini North over a number of semesters. We report here on the first two years of operations and radial velocity observations. MAROON-X regularly achieves sub-m/s RV performance on sky with a short-term instrumental noise floor at the 30 cm/s level. We will discuss various technical aspects in achieving this level of precision and how to further improve long-term performance
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.